User ManualTable of ContentsNFPA Standards4NFPA Standards4Underwriters Laboratories Documents4Other41. Product Description7Overview7Features7Options7Circuits8Input Circuits8Output circuits8Front Panel Control Switches8Suplemental Documentation8Control Panel9DIP Switch Functions10Options10Transmitter Module - 4XTM10Zone Relay Module - 4XZM10Remote Annunciator - RZA-4X11LED Interface Module - 4XLM11Meter Module (Volts-Amps) - 4XMM11Specifications12AC Power12Battery (lead acid only)12Initiating Device Circuits12Notification Appliance and Releasing Circuits12Alarm and Trouble Relays12Resettable Power12Nonresettable Power12RMS Regulated Power122. Installation13Cabinet Mounting13Removal of Circuit Board13Mounting of Cabinet13Attaching Conduit13Reinstallation of Circuit Board14Installing Optional Voltmeter/Ammeter15Power Connections16AC Connections16Battery (DC) Connections16Power-limited Wiring Requirements17Initiating Device Circuits18Four-Wire Smoke Detector Connections19Output Circuits20Notification Appliance Circuits20Releasing Circuits21Alarm Relay Circuit22Trouble Relay Circuit22Powering External Devices22Optional Modules23Overview23Installation - Upper Position23Installation - Lower Position24Setup and Configuration25Transmitter Module - 4XTM25Zone Relay Module - 4XZM26LED Interface Module - 4XLM27Setting Mode of Operation28Basic Program28Discharge Timer29Power-Up Procedure303. System Operation31System Status LEDs31Control Switches32Zone Status LEDs32Piezo33Supervisory Service33Zone Disable33Last Event Recall34Non-Silenceable Service34Sprinkler Supervisory Tracking34System Events34Standby Condition34System Trouble Condition34Single Zone in Alarm (Cross Zone) Condition35Both Zones in Alarm (Cross Zone) Condition35Brownout Condition35Appendix A: Secondary Power Calculations37Standby Battery Requirements37Calculating the Battery Capacity38Appendix B: Compatible Devices39Two-wire Smoke Detectors, UL Listed39Four-wire Smoke Detectors, UL Listed40FM Approved Releasing Devices40Notification Appliances, UL Listed41Door Holders, UL Listed4324 VDC Relays, UL Listed43Appendix C: NFPA Standard-Specific Requirements45Minimum System Requirements45Additional Requirements45NFPA 72 - Signaling Systems for Central Station Service (Protected Premises Unit)45NFPA 72 - Auxiliary Fire Alarm System45NFPA 72 - Remote Station Fire Alarm System45Digital Alarm Communicator/Transmitter - Noti-Fire 911AC46Universal Digital Alarm Communicator - 411UDAC47Local Energy Municipal Box48Remote Station Receiver - RS82-949Appendix D: Testing & Maintenance51Testing51Inspection51Alarm Test51Maintenance51Troubleshooting51Size: 1.8 MBPages: 56Language: EnglishOpen manual
User ManualTable of ContentsNFPA Standards4NFPA Standards4Underwriters Laboratories Documents4Other41. Product Description7Overview7Features7Options7Circuits8Input Circuits8Output circuits8Front Panel Control Switches8Suplemental Documentation8Control Panel9DIP Switch Functions10Options10Transmitter Module - 4XTM10Zone Relay Module - 4XZM10Remote Annunciator - RZA-4X11LED Interface Module - 4XLM11Meter Module (Volts-Amps) - 4XMM11Specifications12AC Power12Battery (lead acid only)12Initiating Device Circuits12Notification Appliance and Releasing Circuits12Alarm and Trouble Relays12Resettable Power12Nonresettable Power12RMS Regulated Power122. Installation13Cabinet Mounting13Removal of Circuit Board13Mounting of Cabinet13Attaching Conduit13Reinstallation of Circuit Board14Installing Optional Voltmeter/Ammeter15Power Connections16AC Connections16Battery (DC) Connections16Power-limited Wiring Requirements17Initiating Device Circuits18Four-Wire Smoke Detector Connections19Output Circuits20Notification Appliance Circuits20Releasing Circuits21Alarm Relay Circuit22Trouble Relay Circuit22Powering External Devices22Optional Modules23Overview23Installation - Upper Position23Installation - Lower Position24Setup and Configuration25Transmitter Module - 4XTM25Zone Relay Module - 4XZM26LED Interface Module - 4XLM27Setting Mode of Operation28Basic Program28Discharge Timer29Power-Up Procedure303. System Operation31System Status LEDs31Control Switches32Zone Status LEDs32Piezo33Supervisory Service33Zone Disable33Last Event Recall34Non-Silenceable Service34Sprinkler Supervisory Tracking34System Events34Standby Condition34System Trouble Condition34Single Zone in Alarm (Cross Zone) Condition35Both Zones in Alarm (Cross Zone) Condition35Brownout Condition35Appendix A: Secondary Power Calculations37Standby Battery Requirements37Calculating the Battery Capacity38Appendix B: Compatible Devices39Two-wire Smoke Detectors, UL Listed39Four-wire Smoke Detectors, UL Listed40FM Approved Releasing Devices40Notification Appliances, UL Listed41Door Holders, UL Listed4324 VDC Relays, UL Listed43Appendix C: NFPA Standard-Specific Requirements45Minimum System Requirements45Additional Requirements45NFPA 72 - Signaling Systems for Central Station Service (Protected Premises Unit)45NFPA 72 - Auxiliary Fire Alarm System45NFPA 72 - Remote Station Fire Alarm System45Digital Alarm Communicator/Transmitter - Noti-Fire 911AC46Universal Digital Alarm Communicator - 411UDAC47Local Energy Municipal Box48Remote Station Receiver - RS82-949Appendix D: Testing & Maintenance51Testing51Inspection51Alarm Test51Maintenance51Troubleshooting51Size: 1.8 MBPages: 56Language: EnglishOpen manual