Precor EFX576i Manual De Usuario

Descargar
Página de 114
User's Reference Manual: Heart Rate Features 
13 
 
 
Troubleshooting Heart Rate 
The following table may help you understand and troubleshoot 
erratic heart rate readings. 
Important: A heart rate can only be detected when the Precor 
heart rate receiver is properly installed in the display. A user must 
wear the chest strap or grasp both touch-sensitive grips. 
Table 2. Erratic heart rate readings 
What 
appears 
on the 
display 
Cause 
What to do 
Nothing 
The heart rate receiver is 
not installed or it has 
been disconnected. 
Call Customer Support. Refer to 
Obtaining Service
HR or Hr 
A signal is being 
detected through the 
chest strap or the 
touch-sensitive grips, but 
a valid heart rate is not 
yet established. 
Be sure that the chest strap is 
moist, centered, and in direct 
contact with your skin. If you are 
using the touch-sensitive grips, 
continue to grasp both of them. 
Wait a few moments for your 
heart rate to appear. 
Note: To conduct electrical impulses from a user’s heart, both 
touch-sensitive grips must be grasped firmly for five to ten seconds. 
Usually, the concentration of salts in a person’s perspiration 
provides enough conductivity to transmit a signal to the receiver in 
the display console. However, because of body chemistry or erratic 
heartbeats, some people cannot use the touch-sensitive grips. A 