Dimension One Spas 2003 Manual De Usuario

Descargar
Página de 44
Aquatic Fitness System 
2003 Owner’s Manual 
 
Troubleshooting Guide 
Heating System 
Symptom 
Problem 
Corrective Action 
1. 
Temperature setting is too low 
1. 
Turn up the thermostat 
2. Dirty 
filter 
2. Clean 
filter 
Does not heat 
3. 
Flow switch out of adjustment 
3. 
Call for service 
1. 
Temperature setting is to high 
1. 
Turn down the thermostat 
Too hot 
2. 
High limit tripped 
2. 
Call for service 
Flashing temperature of 34°F or 134°F 
appears on the display 
Possible temperature sensor failure 
Call for service 
Electrical System 
Symptom 
Problem 
Corrective Action 
Will not turn on – in any mode 
No power 
Check circuit breaker and/or GFCI 
Turns on by itself 
Normal automatic daily power filtration, or 
anti-freeze cycle 
No action required 
Light is out 
Burned out bulb 
Replace bulb 
1. 
Automatic 30-minute timer has shut 
pump off 
1. 
Push JETS pad again to start another 
30-minute cycle 
Pump shuts down unexpectedly while in 
use 
2. 
Motor over-heated and automatic 
protective device has shut down 
pump(s) 
2. 
If pump(s) will not restart when JETS 
pad is pushed, call for service 
 
Make sure that the equipment panel 
vent area is not blocked. Vent 
blockage can cause serious damage to 
your equipment. 
1. 
Check water level 
2. Clean 
filter 
If problem persists: 
1. 
Turn off power 
2. Restart 
the 
system 
If problem persists: 
 3 flashing LEDs appear on the Top Side 
Control 
Possible sensor errors 
Call for service 
Water System 
Symptom 
Problem 
Corrective Action 
Pulsating jets 
Water level too low 
Fill with water to 1” to 2” (2 to 5 
centimeters) above the bottom of the tile 
line 
1. 
HydroTherapy Jets closed 
1. Open 
Jets 
2. Diverter 
Valve 
turned 
2. Turn the Diverter Valve clockwise or 
counter clockwise  
3. Dirty 
Filter 
3. Clean 
Filter 
4. Air 
lock 
4. Loosen 
pump union to allow air to 
escape 
No Jet Action, or action is poor 
5. 
Gate valve closed 
5. 
Open gate valve 
1. Check 
TA/pH 
2. 
Test and adjust 
The water is cloudy or has a smell 
The water has a chemical imbalance. 
3. 
Change Water if necessary 
 
 
 
35