4. Interface type 
TSC -34/RU has serial and USB interface type. You choose either type. You cannot use both these at the 
same time. 
(Notice) In the state that connected a serial and a USB cable to a computer, please do not start power on 
of TSC-34/RU and computer. Because it may cause malfunction. 
 
4-1. Serial mode 
In serial mode, please use CN5 for connecting to host computer, and CN6 for power supply. 
 
Specifications 
Transmission format: Asynchronous serial 
Transfer rate: 
9600bps 
Data format: 
8 bit 
Stop bit:   
1 bit 
Parity:  
None 
 
 
4-2. USB mode 
In USB mode, please use CN4 for connecting to host computer. When you input power supply from CN6, 
please connect also the Vbus line of the USB (CN4). Because TSC-34/RU recognizes that it was con-
nected to the host computer with a Vbus line. 
 
Specifications 
Transmission spec:  USB Specification 2.0 Full Speed 
Transfer mode: 
Control transfer (Command) / Interrupt transfer (Coordinate) 
Device class: 
Vendor definition