APC BE750G Manual De Usuario

Installation Guide
Back-UPS
Back-UPS
™
BE750G Series
Specifications
Inventory
Safety
This UPS is intended for indoor use only.
Do not operate this UPS in direct sunlight, in
contact with fluids, or where there is
excessive dust or humidity.
contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the UPS are not
blocked. Allow adequate space for proper
ventilation.
blocked. Allow adequate space for proper
ventilation.
The battery typically lasts for two to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality utility power, and frequent
short duration discharges will shorten battery life.
battery life. Elevated ambient temperatures, poor quality utility power, and frequent
short duration discharges will shorten battery life.
Connect the Back-UPS power cable directly to a wall outlet. Do not use surge
protectors or extension cords.
protectors or extension cords.
Input
Voltage
120 Vac
Nominal
Frequency
50 Hz/60 Hz auto sensing
Brownout Transfers
92 Vrms Typical
Over-voltage Transfer
139 Vrms Typical
Output
UPS Capacity
(5 battery backup outlets)
(5 battery backup outlets)
750 VA, 450 W
Total Amperage (all outlets)
12 A (including UPS output)
Voltage - On Battery
115 Vrms ± 8% step approximated sine wave
Frequency - On Battery
50 Hz/60 Hz ± 1 Hz
Transfer Time
6 ms Typical, 10 ms maximum
Protection and
Filtering
Filtering
AC Surge Protection
Full time, 354 Joules
Phone/DSL/FAX surge protection
Single line (2 wire)
Cable/CAT V/DSS surge protection
One coax input/output
Network surge protection
10/100 Base -T ethernet
EMI/RFI Filter
Full time
AC Input
Resettable circuit breaker
Battery
Type
Sealed, maintenance-free, lead acid
Replacement battery cartridge RBC17
Replacement battery cartridge RBC17
Average Life
3 - 5 years depending on the number of discharge cycles and
environmental temperature
environmental temperature
Physical
Net Weight
11 lb (5 kg)
Dimensions
Length x Width x Height
Length x Width x Height
14 in x 7 in x 4 in
36 cm x 18 cm x 9 cm
36 cm x 18 cm x 9 cm
Operating Temperature
32º F to 104º F (0º C to 40º C)
Storage Temperature
5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity
0 to 95% non-condensing humidity
Operating Elevation
0 to 10,000 ft (0 to 3000 m)
EMC
Compliance
Compliance
This device complies with part 68 and part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
bu
0
7
5c
Back-UPS