Configuring the RC/GS and RC7
975-0210-01-01
15
Max Charge Rate
The battery charger’s maximum output current can be 
specified using the Max Charge Rate menu. The default is 
100% of the maximum charge rate. Refer to the RV Series 
Inverter/Charger Owner’s Manual for model-specific 
adjustable charge rates in amps.
Set Shore Power
The inverter monitors the AC power being drawn by both the 
battery charger and the AC loads connected to the inverter. If 
the current draw approaches the shorepower circuit breaker 
rating, the battery charger reduces the amount of current 
supplied to the batteries to provide the maximum current to 
the AC loads. Set Shore Power ensures the battery charger 
does not exceed the shorepower circuit breaker rating. This 
setting should match the shorepower or generator’s circuit 
breaker rating. The default setting is 30 amps (and above).
Maximum
Minimum
Default
Step Size
100%
10%
100%
10%
Figure 3-6 Max Charge Rate menu items
Note:
The maximum current draw from the RV3012GS charger 
is 28 amps.
Note:
This setting does not prevent the loads from exceeding 
the shore circuit breaker rating.
Maximum
Minimum
Default
Step Size
30 A or more
5 Amps
30 Amps
5 Amps
Max Charge Rate:
100% of max
Max Charge Rate:
90%
Max Charge Rate:
80%
Max Charge Rate:
20%
Max Charge Rate:
10%
RC-GS_manual.book  Page 15  Thursday, May 26, 2005  4:58 PM