Honeywell DCP200 Manual De Usuario
DCP200 Profile Controller & Recorder - Product Manual
Page 58
Configuration & Use
51-52-25-150, Issue 1 – April 2009
Table 19. Automatic Tuning Menus Screens
Automatic Tuning Menu:
Automatic Tuning Mode
Unlocking
Unlocking
Enter correct code number to access the Automatic Tuning Menu.
w Turns Pre-Tune on/off. Pre-Tune is disabled in On-Off Control Mode;
if the PV is less than 5% of span from SP; during Profiles or if the
Setpoint is Ramping.
Setpoint is Ramping.
Pre-Tune Status
Shows the current Pre-Tune status. Active or Inactive.
Self-Tune
Turns Self-Tune on/off. Self-Tune is disabled in On-Off Control
Mode.
Mode.
Self-Tune Status
Shows current Self-Tune status. Active or Inactive.
Auto Pre-Tune Enable
Enables/Disables Automatic Pre-Tune. When enabled, this attempts
to perform a Pre-Tune at every power-up. Normal Pre-Tune
engagement rules are applied (see Pre-Tune above).
to perform a Pre-Tune at every power-up. Normal Pre-Tune
engagement rules are applied (see Pre-Tune above).
Profiler Setup Menu
Refer to the Profiler Option section of this manual for more details about the profiler features.
Screens marked will not time-out automatically. They must be completed for a valid profile
to be created.
to be created.
Table 20. Profiler Setup Menu Screens
Profiler Menu:
General
General Profile Configuration: Settings that apply to all profiles
Profile Run/Hold
Signal
Profile Run/Hold
Signal
Selects the method used to Run or Hold a profile. From: Digital Input
A; Digital Input B or Key Pad Only (using the either the Profile
Control Menu or an Operation Mode screen).
A; Digital Input B or Key Pad Only (using the either the Profile
Control Menu or an Operation Mode screen).
Profile Abort
Signal
Signal
Selects the method used to force a profile to end prematurely. From:
Digital Input A; Digital Input B or Key Pad Only (using either the
Profile Control Menu or an Operation Mode screen).
Digital Input A; Digital Input B or Key Pad Only (using either the
Profile Control Menu or an Operation Mode screen).
Control In
Operation Mode
Operation Mode
Enables/disables the ability to control profiles (run, hold or abort)
from Operation Mode.
from Operation Mode.
Enable Edit While
Running
Running
Enables/disables the ability to edit profiles whist a profile is running
(even if selected, the current or next segment of the running profile
will not change until after the profile is restarted).
(even if selected, the current or next segment of the running profile
will not change until after the profile is restarted).
Create A Profile
Creates a new profile. A header is created first, followed by the
segments – see below. A warning is displayed if the maximum
number of 64 profiles or 255 segments is exceeded.
number of 64 profiles or 255 segments is exceeded.