Garmin 405 Manual De Usuario

Descargar
Página de 52
 
Forerunner 405 Owner’s Manual
Using Accessories
2.  Press 
start
 to begin recording.
3.  Run or walk approximately 
1000 m. The Forerunner informs 
you that you have traveled far 
enough. 
Manual Calibration
If your foot pod distance seems 
slightly high or low each time you 
run, you can manually adjust the 
calibration factor. 
Touch and hold 
menu
 > select 
Settings
 > 
ant+Sport
 > 
accessories
 > 
Foot Pod
 > 
Cal 
Factor
. Adjust the calibration factor. 
Increase the calibration factor if your 
distance is too low; decrease the 
calibration factor if your distance is 
too high. 
GSC 10
Your Forerunner is compatible with 
the GSC 10 speed and cadence bike 
sensor. You must pair the GSC 10 
with your Forerunner. See 
Calibrating the Bike 
Sensor
Calibrating your bike sensor is 
optional and can improve accuracy.
1.  Touch and hold 
menu
 > select 
Settings
 > 
ANT+Sport
 > 
Accessories
 > 
Bike Sensor
 > 
Calibration
2.  Select 
Manual
 to enter the wheel 
size. Select 
Auto
 to allow GPS to 
determine your wheel size.