Siemens LR 460 Manual De Usuario

Descargar
Página de 123
7ML19985JM01
SITRANS LR 460 – INSTRUCTION MANUAL
Page 59
mmmmm
Pa
ra
m
e
te
rs
3.5.6.3. TVT Hover Level 
Defines in percent how high the TVT (Time Varying Threshold) curve is 
placed above the echo profile, with respect to largest echo.
3.5.6.4. Manual TVT Shaper Mode
Enables the TVT curve to be manually adjusted at a specified range.
3.5.7.  Manual TVT shaper
You can manually adjust the TVT curve by entering values for up to 120 
breakpoints on the curve.
Use this feature to bias the shape of the TVT curve to avoid selecting false 
echoes from fixed objects.
Each breakpoint is normalized to a value of 0. Change the value of the 
breakpoints to adjust the curve. In the case of multiple false echoes, shaping can 
be applied along different points of the curve. Shaping should be applied 
sparingly in order to avoid missing the true echo.
The Manual TVT shaper feature allows you to adjust the TVT curve while viewing 
the echo profile. 
To change a breakpoint via PDM:
a. Confirm that Shaper Mode is selected.
b. Open the menu Device – TVT Shaper then either adjust the curve manually, or 
enter values for the desired breakpoints. (See 
38.)
To change a breakpoint via the handheld programmer:
a. Confirm that Shaper Mode is selected.
b. Access the submenu for the breakpoint number in question and enter values 
for all desired breakpoints.
3.5.7.1. Shaper A (1 - 9). 
3.5.7.2. Shaper B (10 - 18)
3.5.7.3. Shaper C (19 - 27)
Values 
Range: 0 to 100%
Default: 40%
Options 
ON
*
OFF
Values
Range: -50 to 50
Preset: 0
Related