TROUBLESHOOTING & REPAIR
F-7
F-7
TROUBLESHOOTING GUIDE
Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
FEEDING PROBLEMS
No ouput. Main fuses open, indicat-
ing excessive current draw.
Inspect input leads for possible
shorts or grounds or misconnec-
tions.
Install new fuses and reapply power.
If fuses open again, go to next col-
umn of this Guide.
Inspect interior of machine for phys-
ical signs of electrical and heat dam-
age. Replace any damaged compo-
nents after conducting the tests
below:
1.
test.
2.
test.
3.
tests.
4.
test.
Machine does not produce more
than 250 amps on meter (while
welding) while connected to single-
phase supply
Normal operation.
Nothing is wrong.
No test necessary. The single-
phase operation is detected by the
Protection Board and the output cur-
rent is limited accordingly.
Machine operates okay at 230 VAC
or lower. No output at 380 VAC or
higher
Check input voltage and input volt-
age reconnect procedures. See
Installation section of this manual.
1.
Check Re-connect Switches
2.
test.
3.
tests.
4.
test.
5.
test.
Machine does not produce more
than 250 amps on meter (while
welding) when connected to 
3-phase supply.
Check input voltages, fuses, and
input voltage reconnect procedures.
See Installation section of this man-
ual.
1.
test.
2.
Control Board may be defective.
3.
test (com-
ponent D13).
V300-I
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.  Call
1-888-935-3877.