7ML19985GE01
SITRANS LC 500 – INSTRUCTION MANUAL 
Page 7
mm
mmm
Spec
ificat
ions
Process Conditions
Pressure rating
1
• standard
FV (full vacuum) to 200 bar (2920 psi) 
• option
up to 525 bar (7665 psi) 
Temperature rating
• standard
–200 
°
C to 200 
°
(
–328 
°
F to 392 
°
F
)
• option
up to 400 
°
C (752 
°
F
Approvals
CE
Complies with the requirements of E.C.C. as per EN 55011 
and EN 61326
Dust Ignition Proof (DIP)
ATEX II 3GD (EEx nA [ib] IIC T4...T6) 
FM/CSA: 
Class I, Div. 2, Gr. A,B,C,D T4
Class II, Div. 1, Gr. E,F,G T4
Class III, Div. 1, Gr. E,F,G T4
Intrinsically Safe (IS)
ATEX II 1 G (EEx ia IIC T4...T6)
FM/CSA:
Class I, Div. 1, Gr. A,B,C,D T4
Flame-proof/
ATEX II 1/2 GD (EEx d [ia] IIC T6...T1) 
Explosion-proof enclosure FM/CSA: Class I, Div. 1, Gr. A,B,C,D T4
Sanitary 3A
Lloyds Register of Shipping 
Categories ENV1, ENV2, ENV3, ENV5
European Pressure, PED 
97 / 23 / EC
1.
Please refer to page 18, Temperature/ Pressure Curve chart, for specific combi-
nations of temperature and pressure.
Note: 
 on page 96 for details of certification.