Woodstock M1001 Manual De Usuario

Descargar
Página de 44
-12-
M1001 6" x 26" Vertical Mill
EL
EC
TR
IC
A
L
Grounding & Plug Requirements
This machine MUST be grounded. In the event of certain 
malfunctions or breakdowns, grounding reduces the risk of 
electric shock by providing a path of least resistance for 
electric current.
Grounding Prong
Neutral Hot
5-15 PLUG
GROUNDED
5-15 RECEPTACLE
110V
Figure 1. Typical 5-15 plug and receptacle.
For 110V operation: This machine is equipped with a 
power cord that has an equipment-grounding wire and a 
grounding plug (similar to the figure on the right). The 
plug must only be inserted into a matching receptacle 
(outlet) that is properly installed and grounded in 
accordance with all local codes and ordinances.
For 220V operation: The plug specified under “Circuit 
Requirements for 220V” on the previous page has a 
grounding prong that must be attached to the equipment-
grounding wire inside  the included power cord. The plug 
must only be inserted into a matching receptacle (similar 
to the figure on the right) that is properly installed 
and grounded in accordance with all local codes and 
ordinances.
Grounding Prong
Current Carrying Prongs
6-15 PLUG
GROUNDED
6-15 RECEPTACLE
Figure 2. Typical 6-15 plug and receptacle.
Serious injury could occur if you con-
nect  the  machine  to  power  before 
completing  the  setup  process.  DO 
NOT connect to power until instructed 
later in this manual.
Improper connection of the equipment-grounding wire 
can result in a risk of electric shock. The wire with 
green insulation (with or without yellow stripes) is the 
equipment-grounding wire. If repair or replacement of 
the power cord or plug is necessary, do not connect the 
equipment-grounding wire to a live (current carrying) 
terminal.
 
Check with a qualified electrician or service personnel 
if you do not understand these grounding requirements, 
or if you are in doubt about whether the tool is 
properly grounded. If you ever notice that a cord or 
plug is damaged or worn, disconnect it from power, and 
immediately replace it with a new one.
Extension Cords
We do not recommend using an extension cord with this 
machine. If you must use an extension cord, only use it if 
absolutely necessary and only on a temporary basis.
Extension cords cause voltage drop, which may damage 
electrical components and shorten motor life. Voltage 
drop increases as the extension cord size gets longer 
and the gauge size gets smaller (higher gauge numbers 
indicate smaller sizes).
Any extension cord used with this machine must contain a 
ground wire, match the required plug and receptacle, and 
meet the following requirements:
Minimum Gauge Size ................................. 12 AWG
Maximum Length (Shorter is Better) ................50 ft.
Voltage Conversion
The voltage conversion MUST be performed 
by a qualified electrician. To perform the 
voltage conversion, install the correct plug 
and rewire the motor to the new voltage, 
according to the provided wiring diagram. 
If the diagram included on the motor 
conflicts with the one in this manual, the 
motor may have changed since the manual 
was printed. Use the diagram provided on 
the motor.