EMC CLARiiON CX300, CX500, and CX700  Initialization Guide
Initializing the Storage System
5. Specify the following for SP A:
a. IP address
b. Hostname
c. Subnet Mask 
d. Gateway address for SP A
e. Peer IP address for SP B
f. If desired, for example, for added security (see the caution 
below), change the management port setting to 2162/2163.
CAUTION
!
Be sure that this is the management port whose setting you want to 
change. If you later want to change it back, you must remove the 
node from its domain before you can change its port setting from 
the default.
If you do change the management port setting, you will need to 
append the URL with :2162 whenever you want to manage the 
storage system. 
For a description of Navisphere 6.X security features, refer to the 
EMC Navisphere Version 6.X Security Administrator’s Guide.
6. Click Apply Settings
After about 30 seconds, a confirmation screen opens, similar to 
the one in Figure 3. The screen lists the network configuration 
information you entered in step 5, and includes a message 
informing you that SP A is rebooting.
You will set security in a later step.
7. Close the Storage Processor Network Configuration 
confirmation screen.