Honeywell TE532ELW Manual De Usuario

Descargar
Página de 6
10
9
12
11
The unit is in a searching mode.
Temperature and readings is 
securely registered.
No signals detected.
- - -
GETTING STARTED
WEATHER DISPLAY
After batteries are installed; remote sensor will transmit 
temperature and humidity data at 45 second intervals. The 
main unit may take up to two minutes to receive the initial 
readings. Upon successful reception, remote temperature 
will appear under the weather forecast section of the main 
unit’s display (the default remote channel is channel one). 
The main unit will automatically update readings at 45-
second intervals.
After communication between the main unit and remote 
sensor has been established, secure the remote sensor in 
the desired location.
If no signal is received from the remote sensor within two 
minutes, dashes [- - -] will be displayed. Press and hold the 
DOWN (     ) button on the main unit for two seconds to 
initiate another signal search.
 
PLACEMENT OF THE UNITS
The main unit can be placed on any flat surface indoors
The remote sensor can be placed indoors or outdoors, on 
a flat surface or mounted on the wall.
NOTE: When the temperature falls below freezing, the 
batteries in the outdoor remote sensor may have reduced 
voltage supply and a shorter effective range. We 
recommend using lithium batteries at temperatures of 
32°F (0°C) and below.
BATTERY INSTALLATION
REMOTE SENSOR
NOTE: Install the batteries; select the channel and 
temperature in °C or °F before mounting the remote 
sensor.
• Remove the screws from the battery compartment with a 
small Phillips screwdriver.
• Set the channel. The switch is located in the battery 
compartment. Channel 1 is typically selected if only one 
remote sensor is being used.
• Install 2 “AAA” size alkaline batteries (not included) 
matching the polarities shown in the battery compartment.
• Replace the battery compartment door and secure the 
screws.
• Secure the remote sensor in the desired location.
 
MAIN UNIT
• Remove the battery compartment door.
• Install 2 batteries (UM-3 or “AA” size 1.5V) matching 
the polarity as shown in the battery compartment.
• Replace the battery compartment door.
LOW BATTERY WARNING
A low-battery indicator [     ] will appear next to the indoor 
or remote data reading line of the main unit warning that 
the corresponding batteries need replacement.
REMOTE AND INDOOR TEMPERATURE & HUMIDITY
The remote temperature and humidity information line is 
located right below the weather forecast line of the main 
unit’s display.
The wave icon is located above the remote channel number 
indicates the reception status from the corresponding remote 
sensor.
There are three following types of the reception status may 
be displayed:
The indoor temperature and humidity with the icon       is 
located below the remote temperature and humidity 
information line.
NOTE: If the indoor or remote temperature or humidity 
goes above or below operating range stated in 
specifications, the main unit’s display ( weather) will show 
dashes “- - -” on the corresponding line.
AUTO-SCANNING
Press and hold the CHANNEL button for 2 seconds – the 
icon “      ” will appear on the main unit display to the left 
of the COMFORT LEVEL indicator.
All three remote channels data will be displayed one-by-
one automatically with 11 seconds delay in the following 
sequence: Channel 1, Channel 2 and Channel 3.
To exit from scanning mode, press and hold the 
CHANNEL button for 2 seconds, and the icon “      ” will 
disappear, returning the main unit display to the default 
display mode.
PROGRAMMABLE TEMPERATURE ALARM
This product allows manual programming of a HIGH and 
LOW temperature alarms for all three remote channels at 
the same time. Once the actual remote temperature will 
reach the pre-set high or low limits, the alarm will sound. 
The alarm can be set for temperature readings between -58 °F 
and 158°F.
To program the temperature alarm for all three remote 
channels,
• Press the TEMP AL button once to enter into the High 
Temperature Alarm programming mode – the 
abbreviation “OF” with the high temperature limit 
symbol (     ) will be displayed on the remote 
temperature line
• Press and hold TEMP AL button until the abbreviation 
OF” will flash
• Use UP(     ) or DOWN(     ) arrow buttons to adjust the 
higher temperature limit
• Press the TEMP AL button to confirm the selected value
• Press the TEMP AL button once to enter into the Low 
Temperature Alarm programming mode – the 
abbreviation “OF” with the low temperature limit 
symbol (     ) will be displayed on the remote 
temperature line
• Press and hold TEMP AL button until the abbreviation 
OF” will flash
• Use UP(     ) or DOWN(     ) arrow buttons to adjust the 
lower temperature limit
• Press the TEMP AL button to confirm the selected value