Maytag MGD9000X Prospecto

Descargar
Página de 1
Gas Dryer
PRODUCT MODEL NUMBERS
MGD6000X, MGD7000X, 
MGD9000X, MGD9000Y
Gas supply
This dryer is equipped for use with Natural 
gas. Dryer can be converted to L.P. gas. When rigid 
pipe is used it should be 1/2" IPS. When acceptable  
to the gas supplier and local codes, 3/8" approved  
tubing may be used for lengths under 20 ft (6.1 m).  
For lengths over 20 ft (6.1 m), larger tubing should be 
used. Pipe-joint compounds resistant to the action of 
L.P. gas must be used. An individual manual shutoff 
valve must be installed within 6 ft (1.8 m) of the dryer 
in accordance with the National Fuel Gas Code ANSI 
Z223.1. 
 
Electrical
A 120-volt, 60 Hz, AC-only, 15 or 20 amp 
fused electrical supply is required. A time-delay fuse or 
circuit breaker and a separate circuit are recommended. 
 
Water
 
(Steam models only)
The dryer must be  
connected to the cold water faucet using new inlet 
hoses. Do not use old hoses. Do not overtighten.  
Damage to the coupling can result.
A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 
Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
Ref. W10057364B 
03/2011
OVERALL DIMENSIONS
Dryer dimensions
For closet installation, with a 
door, the minimum ventilation 
openings in the top and bottom 
of the door are required. 
Louvered doors with equivalent 
air ventilation openings are 
acceptable.
Exhaust venting
Exhaust your dryer to the outside. 4" 
(102 mm) diameter vent is required. Rigid or flexible metal 
exhaust vent must be used. Do not use plastic  
or metal foil vet. Exhaust hood must be at least  
12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
The vent system chart provides venting requirments 
that will help to achieve the best drying performance.
Vent system chart:
  
NOTE: Side and bottom exhaust installations have  
a 90° turn inside the dryer. To determine maximum  
exhaust length, add one 90° turn to the chart.
Recommended installation clearances (dryer only)
Hood styles: A & B are recommended.
C
A
B
27"
(686 mm)
3/4
"*
(18 mm)
38
1/8
"
(968 mm)
31
1
/
8
"
(790 mm)
50
7
/
8
"
(1292 mm)
5
3
/
4
"*
(146 mm)
3
/
4
"*
(18 mm)
18" min.
(457 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
min.
(155 cm
2
)
48 in.
min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
NOTE: Most installations require a 
minimum of 5" (127 mm) clearance  
behind dryer for exhaust vent with  
elbow. See “Venting Requirements.”
Approximate measurement
Front view:
Side view:
Back view:
Vent system chart
Number of 
90° elbows
Type  
of vent
Box/louvered
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Do not use vent runs longer than specified in vent 
length chart.  
 
Determine the number of elbows you will need.
Select the route that will provide the straightest and most direct path outdoors.  
 
Plan the installation to use the fewest number of elbows and turns.  
 
Use the fewest 90° turns possible.
6
1
/
4
"
(159 mm)
29
7
/
8
"*
(759 mm)
3
1
/
2
"*
(89 mm)
5
3
/
4
"*
(146 mm)
6
1
/
8
"*
(156 mm)
14
3
/
8
"
(365 mm)
25
3
/
4
"
(654 mm)
3
/
4
"*
(18 mm)
Gas
Water inlet
Vent