29" Electric Dryer Installation Instructions
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
MEDC200X, MEDC300X
Electrical
This dryer requires a 3 or 4 wire, single 
phase, 120/240 volt, 60 Hz., AC only electrical supply 
(or 3 or 4 wire, 120/208 volt electrical supply, if speci-
fied on the serial/rating plate) on a separate 30-amp 
circuit, fused on both sides of the line. A time-delay 
fuse or circuit breaker is recommended. Connect to 
an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit.
Water
 
(Steam models only)
The dryer must be  
connected to the cold water faucet using new inlet 
hoses. Do not use old hoses. Do not overtighten.  
Damage to the coupling can result.
Exhaust venting
Exhaust your dryer to the outside. 
4" (102 mm) diameter vent is required. Rigid or flexible 
metal exhaust vent must be used. Do not use plastic  
or metal foil vet. Exhaust hood must be at least  
12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
Hood styles: A & B are recommended.
   
4"
(102 mm)
2½"
(64 mm)
     
4"
(102 mm)
      
4"
(102 mm)
B
A
A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 
C
Dryer dimensions
Select the route that will provide the straightest and 
most direct path outdoors.  
 
Plan the installation to use the fewest number of elbows 
and turns.  
 
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
Ref. W10096987 
11/2010 
For closet installation, with a door, the minimum ventilation openings in the top  
and bottom of the door are required. Louvered doors with equivalent air ventilation  
openings are acceptable.
Do not use vent runs longer than specified in vent 
length chart.  
 
Determine the number of elbows you will need.
Most installations require a minimum 5½" (140 mm) clearance   
 behind the dryer for the exhaust vent with elbow. See “Venting  
 Requirements.”
Vent system chart
Number of 
90° elbows
Type  
of vent
Box/louvered
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The Vent system chart provides venting requirements 
that will help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90° 
turn inside the dryer. To determine maximum exhaust 
length, add a 90° turn to the total number of elbows 
when referemcing the chart.
Minimum Required Spacing
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
 
A
B
C
    18"*
(457 mm)
  1"
(25 mm)
29"
(737 mm)
        1"
   (25 mm)
        1"*
    (25 mm)
14" max.*
(356  mm)
   
27
¾"
(705 mm)
  48 in.
  
(310 cm )
2
*
2
       3"*
(76 mm)
       3"*
(76 mm)
  
24 in.
(155 cm )
*
2
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents