65
Remote 
Control
8
s
B
42
000: Disable
001: Enable
002: Pass through
Disable: RCU has 
no effect on HDTV. 
Enabled: RCU controls 
the HDTV. This is the 
power up default on the 
HDTV.
Pass through: RCU 
has no effect on HDTV 
and all RCU command 
codes are transmitted to 
FC via the RS232 port. 
See page 26 for more 
details
Setup wizard
8
s
C
43
000: Disable
001: Enable
(for TV)
Disable: to skip the 
initial setup wizard
Tiling-Mode
8
s
P
50
000: OFF
001: ON
(for DS)
Tiling-Com-
pensation
8
s
Q
51
000: OFF
001: ON
(for DS)
Bezel width  
compensation
Tiling-H by V 
Monitors
8
s
R
52
01x~09x: H
0x1~0x9: V
(for DS)
1.   2
nd
 digital for  
H monitors
2.   3
rd
 digital for  
V monitors
Tiling- 
Position
8
s
S
53
001~025
(for DS)
Copy the screen of 
Position# to identified 
display
Restore 
default
8
s
~
7E
000
Rests HDTV to factory 
setting
NOTE: 
1.  Behavior at lock modes
Lock Mode
Behavior 
Button Lock 
1.  Lock all buttons on the front panel and RCU, except for 
“Power”.
2.  All the SET functions should be workable via RS32, even the 
ones with according hot key in RCU like Mute,…etc.
MENU Lock
1.  Lock “MENU’ key on the front panel and RCU.
2.  The Factory and Hospitality modes should not be blocked 
for the model using MENU-combined key to enter these two 
modes. Alternative approach will be indicated separately if 
any limitation by model.