3.10.  Trigger & Strobe   
The cameras support external trigger by receiving input through the external trigger port. The falling edge and rising 
edge can be detected as trigger according to the modes it supports as per the following table. A software trigger can 
also be used that issues a trigger signal via a software command. Software trigger is supported in modes 0, 12, 13, 15. 
Trigger 
Edge 
Rising Edge or Falling Edge 
Mode 
Fire-i 701/702/810 
Fire-i 501/511/601 
0, 1, 2, 3, 4, 5, 12, 13, 14, 15 
0, 1, 2, 3, 4, 5, 14, 15 
Method Optocoupler 
(Photo-coupler) 
TTL 
Source 
External or Software Trigger 
 
 
 Inquiry Register 
Address 
Name 
Field 
Bit 
Description 
530h TRIGGER
_INQ 
Presence_Inq 
[0] 
Presence of this feature 
Abs_Control_Inq 
[1] 
Capability of control with absolute value 
- [2..3] 
Reserved 
ReadOut_Inq 
[4] 
Capability of reading the value of this feature 
On/Off_Inq 
[5] 
Capability of switching this feature On and OFF 
Polarity_Inq 
[6] 
Capability of changing polarity of trigger input 
 [7..15] 
Reserved 
Trigger_Mode0_Inq 
[16] 
Presence of Trigger Mode0 
Trigger_Mode1_Inq 
[17] 
Presence of Trigger Mode1 
Trigger_Mode2_Inq 
[18] 
Presence of Trigger Mode2 
Trigger_Mode3_Inq 
[19] 
Presence of Trigger Mode3 
 [20..31] 
Reserved 
Control Register 
Address 
Name 
Field 
Bit 
Description 
830h TRIGGER
_MODE 
Presence_Inq 
Presence of this feature 
0:N/A 1:Available 
Abs_Control [1] 
Absolute 
value 
control 
0: Control with value in the Value field 
1: Control with value in the Absolute value CSR 
If this bit = 1, value in the Value field is 
ignored. 
- [2..5] 
Reserved 
ON_OFF 
[6] 
Write:    ON or OFF this feature 
Read:    read a status 
0: OFF,        1: ON   
If this bit=0, other fields will be read only. 
Trigger_Polarity 
[7] 
If Polarity_Inq is “1”, Write to change polarity of 
the trigger input    Read to get polarity of trigger 
input  
If Polarity_Inq is “0”, Read only. (0: Low active 
input, 1: High active input)   
 [8..11] 
Reserved 
Trigger_Mode [12..15] 
Trigger 
mode.(Trigger_Mode_0-15) 
 [16..19] 
Reserved 
Parameter 
[20..31] 
Parameter for trigger function, if required.