Forgot the IP address of 
the ICA-500.   
Check IP address of ICA-500 by using the IP Finder program.   
IP Finder program 
cannot find ICA-500. 
• Re power the ICA-500 if cannot find the unit within 1 
minutes.   
• Do not connect ICA-500 over a router. IP Finder program 
cannot detect ICA-500.   
• If IP address is not assigned to the PC which running IP 
Finder program, and then IP Finder program cannot find 
ICA-500. Make sure that IP address is assigned to the PC 
properly. 
• Antivirus software on the PC might interfere with the setup 
program. Disable the firewall of the antivirus software during 
setting up ICA-500.   
Internet Explorer does 
not seem to work well 
with the ICA-500 
Make sure that your Internet Explorer is version 6.0 or later. If 
you are experiencing problems, try upgrading to the latest 
version of Microsoft’s Internet Explorer from the Microsoft 
webpage at: http://www.microsoft.com/windows/ie. 
IP Finder program fails 
to save the network 
parameters.   
• Don’t leave any space in the name field. Use underline, “_”, 
or dash, “-“ to replace the space, “ “.   
• Network may have trouble. Confirm the parameters and 
connections of the ICA-500.   
Access ICA-500 
Cannot access the login 
page and other web 
pages of ICA-500 from 
Internet Explorer 
 
 
• Another device or computer is already using Maybe the IP 
Address of the ICA-500. To confirm this possible problem, 
disconnect the ICA-500 from the network first, and then run 
the PING utility to check it out.   
• Maybe due to the network cable. Try correcting your 
network cable and configuration. Test the network interface 
by connecting a local computer to the ICA-500 via a 
crossover cable.   
• Make sure the Internet connection and setting is ok. 
• Make sure enter the IP address of Internet Explorer is 
correct. If ICA-500 has a dynamic address, it may have 
changed since you last checked it. 
• Network congestion may prevent the web page appearing 
quickly. Wait for a while. 
The IP address and Subnet Mask of the PC and ICA-500 
must be in the same class of the private IP address on the 
LAN. 
• Make sure the http port used by the ICA-500, default=80, is 
forward to the ICA-500’s private IP address. 
• The port number assigned in your ICA-500 might not be 
available via Internet. Check your ISP for available port. 
• The proxy server may prevent you from connecting directly 
to ICA-500, set up not to use the proxy server. 
• Confirm that Default Gateway address is correct. 
• The router needs Port Forwarding feature. Refer to your 