S2. Voltage Chart
S2.1. Power Top P.C.B.
Note) Indicated voltage values are the standard values for the unit measured by the DC electronic circuit tester (high-impedance) with the chassis taken as standard. 
          Therefore, there may exist some errors in the voltage values, depending on the internal impedance of the DC circuit tester. 
REF No.
PIN No.
REC
IC1004
1
2.8
IC1004
2
0
IC1004
3
1.2
IC1004
4
8.4
IC1004
5
0
IC1004
6
9.4
IC1005
1
3.3
IC1005
2
0
IC1005
3
1.2
IC1005
4
3
IC1005
5
0
IC1005
6
3.3
IC5001
1
1.4
IC5001
2
0.1
IC5001
3
1
IC5001
4
0.7
IC5001
5
1
IC5001
6
0
IC5001
7
2.8
IC5001
8
2.6
IC5001
9
2.6
IC5001
10
2.8
IC5001
11
2.8
IC5001
12
1.2
IC5001
13
1.2
IC5001
14
1.2
IC5001
15
0
IC5001
16
1.2
IC5001
17
1.2
IC5001
18
1.2
IC5001
19
0
IC5001
20
0.2
IC5001
21
0.2
IC5001
22
1.2
IC5001
23
1.2
IC5001
24
0
IC5001
25
1.4
IC5001
26
3
IC5001
27
0
IC5001
28
1.6
IC8001
1
4.9
IC8001
2
0
IC8001
3
0
IC8001
4
0
IC8001
5
4.9
IC9901
1
0
IC9901
2
2.7
IC9901
3
0
IC9901
4
0
IC9901
5
0
IC9901
6
0
IC9901
7
0
IC9901
8
0
Q1001
S
0
Q1001
D
0
Q1001
G
4.1
Q1003
1
3.6
Q1003
2
3.6
Q1003
3
1.7
REF No.
PIN No.
REC
Q1003
4
3.6
Q1003
5
3.6
Q1003
6
3.5
Q1005
S
0
Q1005
D
2.8
Q1005
G
0
Q1006
S
0
Q1006
D
1.8
Q1006
G
0
Q1050
1
3.6
Q1050
2
3.6
Q1050
3
0
Q1050
4
0
Q1050
5
0
Q1070
1
1.4
Q1070
2
0
Q1070
3
3.5
Q1070
4
9.4
Q1070
5
3.5
Q1072
S
0
Q1072
D
0.3
Q1072
G
0
Q8009
1
3.6
Q8009
2
3.6
Q8009
3
0
Q8009
4
0
Q8009
5
3.6
Q8009
6
3.6
QR1001
E
0
QR1001
C
0
QR1001
B
3.6
QR1002
E
0
QR1002
C
0.9
QR1002
B
0
QR1006
E
0
QR1006
C
0
QR1006
B
3.6
QR5001
E
0
QR5001
C
2.7
QR5001
B
0
QR9901
E
2.8
QR9901
C
2.7
QR9901
B
1