Environmental Specifications
Table 7.
Environmental Specifications for the Cisco UCS C460 M2 Server
Environment
Specification
Temperature operating
10°C to 35°C (50°F to 95°F)
Temperature nonoperating
-40°C to 70°C (-40°F to 158°F)
Altitude
-30 to 1,500 m (-100 to 5,000 ft.)
Humidity nonoperating
95%, noncondensing at temperatures of 25°C (77°F) to 30°C (86°F)
Vibration nonoperating
2.2 Grms, 10 minutes per axis on each of the three axes
Shock operating
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the three axes
Shock nonoperating
Trapezoidal, 25 G, tw
o drops on each of six faces ΔV: 175 inches/sec on bottom face drop, 90 inches/sec on
other 5 faces
Safety
UL60 950, CSA60 950, AS/NZS 3562, GB4943-1995, EN60 950 and 73/23/EEC, IEC 60 950, EMKO-TSE (74-
SEC) 207/94, GOST-R 50377-92
SEC) 207/94, GOST-R 50377-92
Emissions
Certified to FCC Class A; tested to CISPR 22 Class A, EN 55022 Class A and 89/336/EEC, VCCI Class A,
AS/NZS 3548 Class A, ICES-003 Class A, GB9254-1998, MIC Notice 1997-42 Class A, GOST-R 29216-91
Class A, BSMI CNS13438
AS/NZS 3548 Class A, ICES-003 Class A, GB9254-1998, MIC Notice 1997-42 Class A, GOST-R 29216-91
Class A, BSMI CNS13438
Immunity
Verified to comply with EN55024, CISPR 24, GB9254-1998, MIC Notice 1997-41, GOST-R 50628-95
Electrostatic discharge
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact discharge without physical
damage
damage
Acoustic
● Sound power: < 7.0 BA at ambient temperature < 23° C measured using the Dome Method
● GOST MsanPiN 001-96
● GOST MsanPiN 001-96
For More Information