SuperView 3000 User Manual
27
6
..
...
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S
ERIAL
C
OMMAND
S
ET
This section discusses the SuperView serial control commands. The command
set provides access to all of the unit’s functions.
An optional software control program, called the Virtual Control Panel (VCP),
is also available. See "Control Software for Windows" on page 37 for more
information on this program.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G E N E R A L
The command set is made up of ASCII characters and is not case sensitive. The
commands can be spelled out or abbreviated. For example, the Brightness
command can be specified as brightness, BRIGHTNESS, BRI, or bri.
The entire serial command set for the SuperView is presented in this chapter.
Both forms of the command (long and short) are listed, as well as their
associated parameters and descriptions. To execute serial instructions, each
command line must be followed by a carriage return.
For example, at the prompt (>), a command would be as follows:
bri 3 123
Typing bri 3 123 will change the brightness of input 3 to a
new brightness value of 123.
Illegal commands or arguments generate error messages and correct usage
instructions.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S E R I A L C O M M A N D S E T U S A G E
The serial command set can be used to control the SuperView. For example, to
set the brightness level of input 1 to 123, type in BRI 1 123. The serial
command set can also be used to find out the current state for a particular
parameter. For example, to find out the brightness level of input 1, type BRI 1.
The SuperView will return the current value (i.e. Brightness = 123).
The uppercase letters in the command name can be used to abbreviate the
command on the prompt line. For example, BRIghtness, you can use BRI, and
for CONTrast, you can use CONT. A space is required between a command
and its argument. To execute serial commands, each command line must be
followed by a carriage return.
The following tables list all of the commands for controlling the SuperView.