Sony DVW-790WS/790WSP Manual De Usuario

Descargar
Página de 314
7-32
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
3.
On the setup menu, adjust as follows.
PAGE
: S15
*VF SETTING
ITEM
: ZEBRA1 APT.LVL
(Factory setting: 10%)
Spec.
: Adjust for the desired width of detection.
4.
On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: TEST SAW 
 OFF
5.
On the setup menu, set as follows.
PAGE
: S15
*VF SETTING
ITEM
: ZEBRA SELECT 
 2
6.
On the setup menu, adjust as follows.
PAGE
: S15
*VF SETTING
ITEM
: ZEBRA2 DET. LVL
Spec.
: Set the condition that zebra pattern
appears at the portion B.
Setting After Adjustment
. On the setup menu, set as follows.
PAGE
: S15
*VF SETTING
ITEM
: ZEBRA SELECT 
 1
PAGE
: S12
*FUNCTION 1/2
ITEM
: TEST OUT 
 ENC
7-19. Zebra Adjustment
Preparation
. ZEBRA switch (viewfinder) 
 ON
. On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: TEST OUT
 R, G or B
PAGE
: S15
*VF SETTING
ITEM
: ZEBRA SELECT
 1
ITEM
: ZEBRA1 APT. LVL
 l%
. OUTPUT/DCC switch (inside panel) 
 CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1 Lens IRIS
Spec.
: A = 100 
±2 IRE (NTSC)
A = 700 
±14 mV (PAL)
Adjustment Procedure
Equipment : Black and white monitor
Test point : TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
: S15
*VF SETTING
ITEM
: ZEBRA1 DET. LVL
Spec.
: Set the condition that zebra pattern
appears at the portions A.
2.
On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: TEST SAW 
 ON
A
A
A
7-19. Zebra Adjustment
B