Sony DXC-190 Manual De Usuario

Descargar
Página de 56
4-6
DXC-190
4-4-6. Auto-Iris VS Level Adjustment
1 Press the step forward button of the commander once.
The mode indicator will display “2D”.
2 Keep the lens iris at 4-4-5 2.
3 Press the data change button to ensure that the
measured voltage is within the specified value range.
4-4-8. WB (3200K preset) Adjustment
1 Press the step forward button of the commander once.
The mode indicator will display “50”.
2 Remove the ND filter.  Adjust the lens iris so that the
VIDEO-OUT image level is set at 65 
±
3 IRE.
4-4-7. AGC MAX Adjustment
1 Press the step forward button of the commander once.
The mode indicator will display “5C”.
2 Install the ND filter (6.25 %).
* Keep the lens iris at 4-4-6 .
3 Press the data change button to ensure that the
measured voltage is within the specified value range.
3 Alternately switch the mode between “50” and “51” by
pressing the MODE  DISPLAY  CHANGE button, and
while doing so, press the data change button so that the
white bright spot is placed over the origin of the vector-
scope.
IRIS-OUT
Image Level
The white bright spot moves 
in this direction when the mode 
indication is "50".
The white bright spot 
moves in this direction 
when the mode 
indication is "51".
All white pattern
Image level of VIDEO OUT
Waveform Monitor
50
65 
±
3 IRE
Subject
Measurement point
Equipment
Display Mode
Specification
All white pattern
Interface Tool TP5 (IRIS OUT)
Oscilloscope (AC 100 mV, 10 
u
s)
2D
700 
±
40 mV
Subject
Measurement point
Equipment
Display Mode
Specification
All white pattern
 VIDEO OUT image level
Waveform Monitor
5C
65 
±
3 IRE
Subject
Measurement point
Equipment
Display Mode
Specification
Subject
Measurement point
Equipment
Display Mode
Specification
All white pattern
 VIDEO OUT white bright spot
Vectorscope
50, 51
The white bright spot is placed
over the origin of the vectorscope.