Object 0x606C: Velocity actual value 
This object is represented in velocity units and is coupled with the velocity used as input 
to the velocity controller.
 
The object is taken from either the position sensor or the 
velocity sensor. In UM=5 (single position loop), this object reflects the load and the motor 
value; in UM=4 (dual loop), object 0x606A determines which sensor is reflected. 
 
Object description: 
Index 606Ch 
Name 
Velocity actual value 
Object code 
VAR 
Data type 
INTEGER32 
Category Mandatory 
 
Entry description: 
Access Read 
only 
PDO mapping 
Yes 
Value range 
INTEGER32 
Default value 
No 
 
Object 0x606D: Velocity window 
This object monitors whether the required process velocity has been achieved after an 
eventual acceleration or deceleration (braking) phase. It is given in velocity units. 
 
Object description: 
Index 606Dh 
Name Velocity 
window 
Object code 
VAR 
Data type 
UNSIGNED16 
Category Optional 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
UNSIGNED16 
Default value 
No 
 
CANopen DSP 402 Implementation Guide 
 
MAN-CAN402IG (Ver. 1.2) 
 
 
98