Avaya 03-300430 Manual De Usuario

Descargar
Página de 2574
HYB-LINE (Hybrid Line)
Issue 1 June 2005
1337
 
Hybrid Circuit and Conference Circuit Test (#57)
This test checks two different port circuit functions. The Hybrid Circuit test performs an analog 
reflective looparound measurement on the port’s hybrid circuitry. The conference circuit test 
performs a conference test on the port’s NPE.
For the Hybrid Circuit Test results to be valid, a voice terminal must be connected to the port 
being tested. The test instructs the on-board microprocessor to put the port in analog reflective 
looparound mode.
The Conference Test is performed only if the Hybrid Test passes. The Conference Circuit Test 
verifies that the Network Processing Element (NPE) is able to correctly conference several test 
tones together.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Enter 
list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter busyout 
board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long 
This should re-establish the linkage between the internal ID and the port. If 
this is not the case, dispatch to check to ensure that there is a valid board 
inserted.
Table 466: Test #56 Hybrid Electronic Power Feed Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3
Table 467: Test #57 Hybrid Circuit and Conference Circuit Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 4