1756 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0 appears in the Error Log only if a Digital Line circuit pack that has ports 
administered has been removed since the Error Log was last cleared. Make sure that the 
circuit pack has been re-inserted.
b. Error Type 1, Aux Data 40987 indicates an off-board problem detected by the port circuit, 
and may result in a noisy port or link. See note n for recommendations.
Note:
Note:
c. Error Type 1, Aux Data 1 - 20 is logged when at least 15 off-board problems have been 
detected with the link to the data module. Each error detected increments an on-board 
counter. The aux data gives the value of this counter divided by 15. The user could 
experience a noisy port or link. See note “n” for recommendations.
Note:
Note:
d. Error Type 15 is an internal that occurs when an audit request fails.
e. Error Type 18 is logged when the port in question is demand busied out Make sure that the 
port is released from busyout.
f. Error Type 257: problems with transmitting to the data module. This is usually an on-board 
problem and can be ignored if no user complaints are received. Otherwise, check for faulty 
wiring.
g. Error Type 769: EPF has been turned off due to the overcurrent condition at the data 
module. See the recommendations in note n. This may also be caused by the PTC being in 
the “tripped” position due to a short on the power line. You can correct this by removing the 
short, unplugging the data module from the wall for about 30 seconds, and plugging it back 
in.
Note:
Note:
h. Error Type 1537: an in-line maintenance error generated an off-board warning due to some 
problem with the link to the data module. This can be ignored if no user complaints are 
received. Otherwise, see Note 
 for recommendations.
Note:
Note:
i. Error Type 2304: indicates an internal error. No action is necessary.
j. Error Type 2305, Aux Data 32770: the data equipment went off-hook while the associated 
link was being initialized (in a disconnected state). Use status data-module to