Conference Circuit Test (#7)
The Conference Circuit test verifies that the NPE channel for the port being tested can correctly 
perform the conferencing function. The NPE is instructed to listen to several different tones and 
conference the tones together. The resulting signal is measured by a tone detector port. If the 
level of the tone is within a certain range, the test passes.
Table 659: Test #7 Conference Circuit Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be in use on a valid call. Use status pri-endpoint extension 
commands to determine when the port is available for testing.
1004
ABRT
The port has been seized by a user for a valid call. Use status 
pri-endpoint extension
 to determine when the port is available for 
testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABRT
The test did not run due to an already existing error on the specific port or a 
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the already existing error.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This will 
cause noisy and unreliable connections.
1. Replace the circuit pack. Even though wideband calls do not use the 
conferencing feature on the NPE, this failure indicates problems with 
the circuit pack hardware.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated using other port tests and 
examining terminal adapter or external wiring.