ADX8D-PT (AUDIX Digital Port)
Issue 1 June 2005
349
 
Crosstalk testing is performed on both the primary (for voice) and the secondary (for data) 
information channel associated with each EMBEDDED AUDIX port. If NPE Crosstalk Test (#9) 
fails on either channel, the voice port is taken out of service.
Table 94: Test #9 NPE Crosstalk Test 
Error
Code
Test 
Result
Description / Recommendation
1
ABRT
During testing of the primary information channel, system resources may 
not have been available. Also, the port may have been busy during the test.
1. Check the port status.
2. Use display port location to determine the voice port extension 
of the port. Use status station to determine the service state of the 
port. If the service state indicates that the port is active, wait until it is 
idle.
3. Retry the command at 1-minute intervals up to 5 times.
2
ABRT
System resources may not have been available, or the port may have been 
busy during the test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be active.
1. Use display port location to determine the voice port extension 
of the port. Use status station to determine the service state of the 
port. If the service state indicates that the port is active, wait until it is 
idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1001
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals up to 5 times.
 1 of 2