Avaya 03-300430 Manual De Usuario

Descargar
Página de 2574
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005
553
 
Expansion Interface Lock Query Test (#304)
This test is nondestructive and is used to query the ATM and EI circuit packs (both active and 
standby) for its status concerning lock to the backplane system clock.  It is run as part of 
periodic, scheduled, initialization, and error analysis testing.  When an in-line, “out-of-lock” 
report comes in, this test is run to check the circuit pack’s status.  The ATM-EI responds with “in 
lock” or “out of lock.” If the response is “in lock,” the test passes; if the response is “out of lock,” 
the test fails.
Table 175: Test #304 Expansion Interface Lock Query Test (#304) 
Error 
Code
Test 
Result
Description / Recommendation
2000
ABRT
Response to the test request was not received within the allowable time 
period.
2100
ABRT
Could not allocate the necessary system resources to run this test.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
A PN’s unduplicated ATM-EI circuit pack responded incorrectly, or a PN’s 
active ATM-EI circuit pack could not communicate with the PN’s circuit 
packs.
1. If the PN’s active ATM-EI circuit pack is failing and duplicated PNC is 
enabled:
a. Enter reset PNC interchange to switch to the standby PNC.
b. Repeat the short test sequence.
c. If test continues to fail, enter reset board location to reset the 
ATM-EI circuit pack.
2. If the PN’s unduplicated ATM-EI circuit pack is failing:
a. Enter display errors and display alarms, and follow the 
associated repair procedures for TDM-CLK, TONE-BD, or SYNC 
alarms/errors.
b. Repeat the short test sequence.
c. If test continues to fail, replace the circuit pack or transceiver.
PASS
Communication from software to the ATM-EI circuit pack is functioning 
correctly.
 1 of 2