Avaya 03-300430 Manual De Usuario
Communication Manager Maintenance-Object Repair Procedures
344 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ADX8D-BD (AUDIX Circuit Pack)
S8700 | 8710
/
S8500
The ADX8D-BD MO defines a TN566/TN2169 EMBEDDED AUDIX circuit pack (also called
DEFINITY AUDIX) operating in DP (digital-port) mode.
For port-level problems, see
DEFINITY AUDIX) operating in DP (digital-port) mode.
For port-level problems, see
For circuit-pack-level problems, see
page 2539.
EMBEDDED AUDIX
EMBEDDED AUDIX
consists of two circuit packs that occupy 5 slots on a port carrier. The tests
described in this manual apply only to switch-side maintenance which tests a circuit pack’s
components related to the TDM-bus interface. The AUDIX system has an extensive
maintenance strategy that is described in EMBEDDED AUDIX System Maintenance,
585-300-110.
components related to the TDM-bus interface. The AUDIX system has an extensive
maintenance strategy that is described in EMBEDDED AUDIX System Maintenance,
585-300-110.
MO Name in Alarm Log
Alarm
Level
Level
Initial Command to Run
Full Name of MO
ADX8D-BD
MIN
WRN
test board location sh
AUDIX circuit pack