1   Measure 2" from the top and each side of the safe’s top interior 
corners. Mark these spots on the safe’s interior with a marker 
(Figure 3). 
2  Using a sharp utility knife cut a 2" x 2" “X” in the carpet where you 
marked. Tape the carpet flaps open using masking tape. Use a 2" 
wood bit to drill though the fire-resistant insulation. Do not attempt 
to drill through the steel safe body with the wood bit. 
3  Use a ½" high-speed bit designed for drilling metal to drill through 
the steel safe wall. Once you have drilled though the fire-resistant 
material and safe body, mark the center of your holes on the wall. 
4   Remove the safe and use a 
 3
/
8
" masonry bit to drill the anchor holes. 
Reposition the safe over the holes and install the expansion anchors 
and washers through the safe interior. Use a minimum of 
 3
/
8
" x 4" 
expansion-type anchor bolts and 1¾" steel washers inside the safe 
body to reinforce the safe wall at the anchor position. 
5   Fill the holes in the safe interior with high-temperature silicone 
caulking and reposition the carpeting “X” cut out. The caulking will 
hold the carpet in place.
 
IMPORTANT: Pre-drill wall anchor holes in the safe prior to 
anchoring the safe to the floor or wall. See “Anchoring Your  
Safe to a Wall” on page 10.
9  Fill the 2" openings in the fire-resistant material with high 
temperature silicone caulking. The caulking will seal the opening 
and prevent hot gases from entering the safe during a fire. (Not 
required on models that are not fire-resistant.)
10  Replace the floor panel, elevation brace and interior shelving.
a n C h o r i n g   t o   a   J o i s t   f l o o r
Important: Pre-drill the pass-through holes in the safe back and floor 
prior to anchoring the safe to the floor or wall.
1  Follow steps 1 – 5 above, but use 
 3
/
8
" x 4" lag bolts.
2  Remove the safe and drill holes in the floor with a 
 5
/
16
" wood bit.
3  Reposition the safe over the holes and install the lag bolts and 
washers through the safe floor. Important: Pre-drill wall anchor 
holes in the safe prior to anchoring the safe to the floor or wall. 
See “Anchoring to a Wall” on page 10.
4   Fill the 2" openings in the fire-resistant material with high 
temperature silicone caulking. The caulking will seal the opening 
and prevent hot gases from entering the safe during a fire. (Not 
required on models that are not fire-resistant.)
5   Replace the floor panel, elevation brace and interior shelving.
a n C h o r i n g   y o u r   s a f e   t o   a   w a l l 
Anchoring to a wall, in addition to the floor, further strengthens your 
anchoring system. (Without wall anchors, the height of the safe allows 
it to be used as a lever to pry against the floor anchors.)
a n C h o r i n g   t o   a   m a s o n ry   wa l l
IMPORTANT: Pre-drill the holes in the safe back and floor prior to 
anchoring the safe to the floor or wall.
figure 3
mark 2" from the top and each side of the safe wall to locate anchor holes.
2"
2"
2"
2"
07-137-BSF_Safe OM.indd   10-11