Desa CB36N Manual De Usuario

Descargar
Página de 36
www.desatech.com
117437-01D
9
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. No gas supply, or shutoff 
valve.is.OFF
..Air.in.gas.line
3..Construction. debris. clog-
ging pilot orifice
4..Low.gas.pressure
5..Kinked.pilot.line
6..Control.valve.is.not.open-
ing
7..No. power. to. unit. or. the.
ignition.module
1..Loose.wiring.on.ignitor.wire.
to. ignition. module. and/
or. poor. ground. to. ignition.
module
..Pilot. flame. too. low. to.
sense
1. Pilot flame may be too low 
to. sense. flame. causing.
ignition. module. to. shut.
down
..Improper. or. restricted.
venting
OBSERVED PROBLEM
Electronic  Ignition  Models 
Only
.Ignitor.will.not.spark.or.
pilot.will.not.light
Electronic  Ignition  Models 
Only 
Pilot.will.not.stay.lit
Electronic  Ignition  Models 
Only 
Frequent.outage.of.main.
burner.and.pilot.after.complete.
ignition.sequence
REMEDY
1..Check.to.see.if.you.have.gas.
supply.and.that.equipment.
shutoff.valve.is.opened
..Repeat. lighting. procedure.
several.times.to.purge.all.air.
out.of.lines..If.after.repeated.
attempts. appliance. does.
not  light,  call  for  qualified 
service.and.repair
3. Remove debris and dirt, and 
inspect.and.clean.any.other.
possible.obstructions
4..Contact. your. gas. supplier.
to.check.pressure
5. Have a qualified technician 
replace.pilot.line
6..Replace.control.valve.(Re-
fer.to.Replacement Parts
page.31)
7..Check. that. main. power. is.
on. and. that. wire. connec-
tions. are. made. correctly.
to. the. ignition. model. (see.
Wiring Diagrams, page 13). 
Check. for. 4. VAC. at. the.
secondary.side.of.the.trans-
former. If 24 VAC is present, 
and. the. module. does. not.
operate,  have  the  module 
replaced. otherwise. have.
the.transformer.replaced
1..Check. wiring. connection..
Refer.to.wiring.diagram.(see.
Wiring  Diagrams,  page  13) 
and/or.check.ground.wire.to.
ignition.module
..Clean and adjust pilot burner 
and. check. gas. supply. and.
inlet. pressure. to. unit.. Note:.
Have  a  qualified  technician 
replace. pilot. assembly. if.
broken.or.corroded
1. Clean and adjust pilot flame 
for maximum flame across 
sensor.rod
..Locate.and.correct.all.vent.
conditions.(see.Checking for 
Proper Venting
, page 10)