Louisville Tin and Stove BBT54 Manual De Usuario

Descargar
Página de 26
VENT CAP CLEARANCES
Page 4
A = Clearance above grade, veranda, porch, deck or balcony
       (*12 inches [30cm] minimum)
B = Clearance to window or door that may be opened
        (*6 inches [15 cm] minimum)
C = Clearance to permanently closed window (minimum 12
        inches [30 cm] recommended to prevent condensation
        on window)
D = Vertical clearance to ventilated soffit located above the
         terminal within a horizontal distance of 2 feet [60 cm]
         from the center-line of the terminal (18 inches [46 cm]
         minimum)
E = Clearance to unventilated soffit (12 inches [30 cm]
        minimum)
F = Clearance to outside corner (12 inches [30 cm]
        minimum)
G = Clearance to inside corner (24 inches [60 cm]
         minimum)
H = *Not to be installed above a meter / regulator assembly
         within 3 feet [90 cm] horizontally from the center-line
        of the regulator
I = Clearance to service regulator vent outlet (*6 feet [1.8 m]
       minimum)
J = Clearance to non-mechanical air supply inlet to building
      or the combustion air inlet to any other appliance (*12
      inches [30 cm] minimum)
K = Clearance to a mechanical air supply inlet (*6 feet
       [1.8 m] minimum)
L = † Clearance above paved side-walk or a paved driveway
       located on public property (*7 feet [2.1 m] minimum)
M = Clearance under a veranda, porch, deck or balcony
        (*12 inches [30 cm] minimum‡)
†  A vent shall not terminate directly above a sidewalk or
    paved driveway which is located between two single
    family dwellings and serves both dwellings*.
‡  Only permitted if veranda, porch, deck or balcony is
    fully open on a minimum of 2 sides beneath the floor.
*  As specified in CGA B149 installation codes, NOTE:
    local codes or regulations may require different
    clearances.
OUTSIDE LOCATION FOR VENT OUTLET TERMINAL
FIG. 1
CLEARANCES TO COMBUSTIBLES
COMBUSTIBLE
CLEARANCE
Floor......................................
0 Inches (0 cm)
Right Side..............................
0 Inches (0 cm)
Left Side................................
0 Inches (0 cm)
Back......................................
0 Inches (0 cm)
Front......................................
16 Inches (41 cm)
Ceiling....................................
36 Inches (91 cm)
Draperies................................
  4 Inches (10 cm)
Vent........................................  2.5 Inches (6.35 cm)
CLEARANCES
If the heater is installed directly
on carpeting, tile or other com-
bustible material other than
wood flooring, the heater shall
be installed on a metal or wood
panel extending the full width
and depth of the heater.