Monessen Hearth DLX18 Manual De Usuario
14D2099
15
Heater in
Fireplace or
Firebox
Fireplace or
Firebox
Heat
Resistant
Material
Resistant
Material
10" and Less
12" 28"
Minimum of 8"
Heat
Resistant
Material
Heat
Resistant
Material
Mantel
Hood
2
1
/
2
"
8"
6"
7"
14
1
/
2
"
4"
Figure 10 is an example of an unsafe mantel installa-
tion. This mantel projects 4" at 8" above the opening,
exceeding the maximum acceptable distance of 2
tion. This mantel projects 4" at 8" above the opening,
exceeding the maximum acceptable distance of 2
1
/
2
"
The mantel also projects 7" at 14
1
/
2
" above the open-
ing, exceeding the maximum acceptable distance of 6".
If your mantel profile is unsafe, you may either:
• Raise the mantel to an acceptable height
OR
• Remove the mantel
CLEARANCES
AND
HEIGHT REQUIREMENTS
Figure 9 - Minimum Mantel Clearance with No Hood — DLX/GLX 24 and 28
Figure 10 - Unacceptable Mantel Clearance
Example:
The bottom of the mantel may project from the wall a
maximum of 10" at a minimum of 28" above the opening.