PROBLEM
SOLUTION
Water vapor & humidity are  
not produced.
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
Tank Installation: Make sure the water tank is  
correctly attached. Make sure spring on tank 
cap moves freely when pushed.
Air blows but water vapor is  
not produced.
Excessive Water: Remove a certain amount of water 
from the tank.
The desired humidity is lower than the current tem-
perature: Increase the desired humidity.
Detergent residue in the tank: Wash the tank out and 
try again.
Humidity level is low.
The surface of the ultrasonic metal disk may be dirty: 
Wipe it off with a dry, soft cloth. Clean with diluted 
vinegar.
The water in the unit is too cold: Replace with cool, 
but not cold water.
Warm humidity is not produced.
It may take 10-15 minutes before warm  
humidity is created. The mist may not feel  
warm  to the touch.
Check to see if base of unit feels warm to the touch. 
If so then warm mist is being produced.
The humidity has a bad smell.
Poor maintenance or dirty water: Clean the product 
thoroughly, and fill it with fresh water.
White dust is forming on  
nearby furniture.
Hard water will deposit a certain amount of 
dust. Dust in the air settles because of the 
added humidity in the room.  
*Use distilled water if this becomes a nuisance.
Always unplug the unit before servicing it in any way.
The temperature of the water remaining in the unit after use may be HIGH.
Do not submerse the unit in water, or allow water to enter anywhere on the unit  
except the designated water tank.
INSIDE THE BODY OF THE UNIT
Pour excess water out of the unit, but do not allow it to enter the hole where the water 
vapor comes out. Wash out the unit with fresh water, using the cleaning brush and a 
soft cloth as needed.
OUTER SURFACE OF THE UNIT
Wipe the surface of the unit with a soft, damp cloth if needed.
WATER TANK
If water spots remain in the water tank, wipe the inside with a soft cloth. 
DO NOT use soap or detergents.
AIR FILTER
Gently wipe away debris from the filter with a soft cloth. 
This filter does NOT need to be replaced.
ULTRASONIC DISK
Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly remove build up 
and deposits from this area (Fig. 2). Diluted vinegar will help to prevent this build up.
Fig. 1
Fig. 2
Fully dry the inside and outside of the unit before storing it.
DO NOT leave water in the unit.
Store in a cool, dry place.