CFM 167219 Manual De Usuario

Descargar
Página de 4
* The sound pressure level dBA has been measured in accordance with the
international standard ISO 3744. It is the average free field value taken at a
radius of 1 meter from the fan, fully ducted, and located above a reflecting
plane.
At present, there is no standard for sone level testing of remote mounted fans.
Sound levels can be affected by the type of duct used, size of duct, distance of
the fan from the interior grille/diffuser, and other pertinent factors. Sound tests
that do not consider these factors are irrelevant.
R
R
Note: AXC models 100A through 300B are UL and CSA listed products.
Note: AXC models 355A and 355B are CSA listed to both US and Canadian standards.
AXC-0910
Distributed By:
Continental Fan Manufacturing Inc.
203 Eggert Road
Buffalo, NY 14215
Tel: 716-842-0670  Toll: 800-779-4021 
Fax: 716-842-0611
www.continentalfan.com
Aeroflo Inc.
12–205 Matheson Blvd. East
Mississauga, Ontario, Canada L4Z 3E3
Tel: 905-890-6192  Toll: 800 -779-4021     
Fax: 905-890-6193 
www.aeroflo.com
MODEL
WATTS AMPS RPM
dBA*
CUBIC FEET PER MINUTE
0”SP
1
/
8
”SP
1
/
4
”SP
3
/
8
”SP
1
/
2
”SP
3
/
4
”SP 1”SP 1
1
/
4
”SP1
1
/
2
”SP 2”SP
3”SP
AXC100A
55
0.57 1750
44
106
99
93
87
80
68
55
39
AXC100B
85
0.69 2400
54
152
146
139
131
124
106
82
66
33
AXC125A
62
0.58 1650
36
159
127
100
82
68
34
AXC125B
85
0.70 2350
53
212
185
162
145
128
79
32
AXC150A
80
0.75 2500
54
247
225
202
178
161
132
92
50
AXC150B
72
0.73 2580
55
309
271
237
202
171
132
107
88
15
AXC200A
72
0.72 2550
56
418
397
366
339
306
233
174
110
56
AXC200B
160
1.52 2700
60
636
618
557
521
494
412
353
271
190
78
AXC250
250
1.94 2650
63
695
659
610
541
500
359
279
197
125
41
AXC300A
190
2.07 2650
68
865
824
765
736
677
553
459
365
283
124
AXC300B
345
2.78 2765
74
1198 1165 1052
981
945
796
615
453
363
178
65
AXC355A
334
2.88 1360
57
1325 1220 1105
985
860
688
550
400
238
AXC355B
830
7.81 2900
77
1400 1375 1360 1335 1285 1220 1135 1075 1000
880
675
MODEL
D
(in.)
d
(in.)
a
(in.)
B
(in.)
WT
(lbs)
AXC100A
9.5
3.9
1.0
8.3
6.5
AXC100B
9.5
3.9
1.0
8.3
6.5
AXC125A
9.5
4.8
1.0
8.3
6.5
AXC125B
9.5
4.8
1.0
8.3
6.5
AXC150A
9.5
5.8
1.0
8.3
6.5
AXC150B
13.2
5.8
1.0
9.1
11.0
AXC200A
13.2
7.8
1.0
9.1
11.0
AXC200B
13.2
7.8
1.0
9.1
11.0
AXC250 
13.2
9.8
1.0
9.1
11.0
AXC300A
15.9
11.8
1.2
11.8
18.0
AXC300B
15.9
11.8
1.2
11.8
20.0
AXC355A
19.0
14.0
1.5
15.7
26.0
AXC355B
19.0
14.0
1.5
15.7
31.0
D
Diim
meen
nssiioon
na
all  D
Da
atta
a
P
Peerrffoorrm
ma
an
nccee  D
Da
atta
a
H
Hoow
w  d
doo  II  k
kn
noow
w  w
wh
hiicch
h  ffa
an
n  iiss  b
beesstt  ssu
uiitteed
d  ffoorr  m
my
y  a
ap
pp
plliicca
attiioon
n??
As previously summarized, there are numerous applications where ventilation is required. Whether it is for residential or
commercial applications, it is imperative that the proper amount of airflow be calculated.
R
Re
es
siid
de
en
nttiia
all
One of our qualified technical support personnel would be happy to assist in selecting a fan for your residential ventilating needs.
If you would like to inform yourself further, HVI, the Home Ventilating Institute provides ventilating guidelines for consumers. For
more information, visit www.hvi.org.
C
Co
om
mm
me
errc
ciia
all
For an application that is commercial or very specific in nature, you may want to enlist an HVAC contractor. For a list of