Gianni Industries P-MU-GS705N-30 Prospecto

Descargar
Página de 2
2-2
1.
Make sure the gap between the door top rail and
frame header is 2mm. Make adjustments to the door
as required.
2.
Adjust single acting door and door closer to insure
the door settles immediately and is fully closed .
( A d j u s t
d o u b l e
a c t i n g
d o o r
a n d
P O S I T I V E
CENTERING DOOR CLOSER to insure the door
settles immediately and is fully closed and rest in the
dead center of the frame.
3.
Locate the vertical centerline of the magnet and
armature as possible to the leading door edge.
4.
Determine the horizontal centerline of the door
top rail thickness. The Armature centerline will be the
same. Mark the door per template.
5.
Before determining the frame header centerline
single acting door must be fully closed. Double acting
doors must be fully closed and rest in the dead center
of the frame. Mark the frame header per the template.
Prepare the door and frame per the template.
6.
Install the Shear lock and armature assembly
towards the leading edge of the door.
7.
For proper operation the armature must be
adjusted upward as close as possible and parallel to
the Shear Lock without interfering with opening and
closing of the door.
8.
Proper operation cannot be expected with more
than 2 mm gap between the armature and the magnet.
Use the key wrench provided to adjust the armature
vertical adjustment screws.
9
With the door closed turn the lock power on, check
the lateral alignment. The armature
locking bolt
should be centered to magnet keep hole.
10.
If the shear stops are too close or binding,
double check the templating and door alignment, and
make corrections as required.
11
Repeat steps 6~10 as necessary following shear
lock replacement. Cycle the door and Shear Lock
several times after the completion of the installation.
Flush Installation
For Vertical Installation
Change the spring which is provided
in the screw pack.
Use tapping
Screws for
wooden door
Leading
edge
of door
Flat Lugs is used when the door frame is deep, and to prevent
the Electromagnetic Lock or the Armature Plate caved in, add
flat lugs to raise the plane (level) of the Electromagnetic Lock
face or the Armature Plate face to the door frame surface.
Make sure the gap between the Shear Lock and the
Armature Plate are the same while adjusting the gap.
Proper operation cannot be expected with
more than 2 mm gap between the armature
and the magnet.
Use the key wrench
provided to adjust the armature vertical
adjustment screws.
key
wrench
T h e G a p b e t w e e n t h e
Lock and Armature plate
is 2 mm
Copyright Gianni Industries, Inc. All Rights Reserved.
Publish
P-MU-GS705N-30 Ver. C
:2007.07.17