III.  The indicator signal chart & Default: 
Green LED  
Relay activated 
Red LED
 
Power on, stand-by 
Yellow LED 
Programming mode 
1 Flashing Yellow LED 
Key-in Code Confirmed 
Blue LED 
Controller Stand-by 
LED signal
 
Flashing Blue LED 
Controller Locked 
Bi 
Key-in, Effective PIN codes 
Bi- x 2 
Entering or Exiting from the Program mode 
Bi- x 3 
Data computing error, other operation 
mistakes 
Audio
 
Bi- x 5 
Master Code reset to default(12345)or 
remove all stored user codes 
 
Master code 
12345 (changeable) 
Time delay of relays 
5 seconds 
Time delay of Keypad 
5 seconds 
Time delay of programming mode 
60 seconds 
Default value
 
Time delay of Invalid PIN Lock-out 
12345 (changeable) 
 
 
 
IV. Wiring Diagram: 
 
 
Attention
‹
 
The varistor or diode must be connected across the lock terminal (electric strike...) operated by the 
device. The varistor controls the overload produced by the strike coil (EMP) 
‹
 
Cutting spare delay time after door closes for anti-passback: Time delay settled in 10 seconds. If the 
door is closed in 3 seconds, the remaining 7 seconds will be ignored and door locks automatically once 
the door closes. 
 
 
V.  Operation Instruction