Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 
 
31
www  GarrettCom  com
.
.
provided on the sides of 6K16V for DIN-Rail mounting 
purposes.  See side view at the left, with the top of the unit 
pointed to the right. The required two screws are included 
with the DIN-Rail brackets, and are no.10-32 X 3/8 PHIL. 
PAN w/star washer. The two heavy duty Din-Rail latches 
are designed as if that they can be manually accessed from 
the top when the 6K16V is installed on a DIN Rail. 
To install the 6K16V with the DIN-Rail brackets and 
latches attached to it, hold the 6K16V in the vertical position 
with the bottom out, and with the top moved in toward the 
DIN-Rail.  Position the latches over the top of the DIN-Rail. 
Then, snap the latches into holding position by moving the bottom of the 6K16V inwards 
to a vertical position. The DIN-Rail latches and brackets are heavy duty, and will hold 
the 6K16V securely in position, even with cabling attached to the unit.  
To release the 6K16V from the DIN-Rail mounting, press the top of the two DIN-
Rail latches down simultaneously to release the 6K16V so that it can be dismounted by 
pulling the bottom out. Once the bottom of the 6K16V is rotated out, the DIN-Rail latch 
is not engaged and the 6K16V can be moved up and out, free of the DIN-Rail mounting.. 
The picture below is a front / right-side view of a DIN-Rail mounted 6K16V. It 
shows vertical mounting of Magnum 6K16V on a DIN-Rail track for proper convection 
cooling of the unit. Note that there is air space in the rear, as the 6K16V unit is held out 
from the rear of the panel by the mounting brackets. The 6K16V design uses the case for 
cooling (patent pending), and needs to be mounted vertically with air flow space in the 
front, rear, 
and sides. 
 
 
 
 
Fig 3.3.1- 
Magnum 6K16V mounted 
vertically with DIN-Rail 
brackets and latches