Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
 * ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
 
1. All filters must be high velocity cleanable type.
2. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
RATINGS & PHYSICAL / ELECTRICAL DATA 
Model
Output
Nominal
Cabinet 
Width
AFUE
Air Temp. Rise
Max. Outlet 
Air Temp.
MBH
CFM
In.
°F
°F
(F,L)C8T060A12UH11
46/34
1200
14-1/2
80.0
25-55
165
(F,L)C8T080A12UH11
64/48
1200
14-1/2
80.0
30-60
175
(F,L)C8T080B16UH11
64/48
1600
17 1/2
80.0
25-55
160
FC8T100B12UH11
80/53
1200
17 1/2
80.0
25-55
170
(F,L)C8T100C20UH11
80/53
2000
21 80.0
25-55
160
FC8T120C16UH11
96/64
1600
21 80.0
25-55
180
(F,L)C8T120C20UH11
96/64
2000
21 80.0
25-55
170
Model
Output
Blower
Blower
Size
Total
Unit
Max Over-current 
Size (awg) @
 75 ft.protect
Min.
Wire
one way
Operation
WGT.
MBH
Hp
Amps
In.
Amps
LBS
(F,L)C8T060A12UH11
46/34
 1/3
6.2
10 x 7
9.0
20
14
107
(F,L)C8T080A12UH11
64/48
 1/3
6.2
10 x 7
9.0
20
14
119
(F,L)C8T080B16UH11
64/48
 3/4
11.5
11 x 8
12.0
20
14
129
FC8T100B12UH11
80/53
 1/2
7.0
10 x 8
12.0
20
14
131
(F,L)C8T100C20UH11
80/53
1.0
12.2
11 x 10
14.0
20
12
149
FC8T120C16UH11
96/64
 1/2
10.4
10 x 10
12.0
20
14
149
(F,L)C8T120C20UH11
96/64
1.0
12.2
11 x 10
14.0
20
12
151
FILTER SIZES
Cabinet Size
Side (in)
Bottom (in)
A
16 x 26
14 x 26
B
16 x 26
16 x 26
C
(2) 16 x 26
20 x 26
D
(2) 16 x 26
20 x 26