Table 7: Oil nozzle capacity 
 
All rates shown achieved with 120 PSIG pump pressure for Beckett and 140 PSIG pump pressure for 
Riello.  
 
* Based on #2 domestic heating fuel oil having heating value of 140,000 BTU per gallon. 
** Based on thermal efficiency of 84%-85%. 
 
 
 
Riello 2-stage burner specifications and applications (OH6 ONLY): 
 
                   MODEL 
 
PART 
OH6 2-STAGE 
MTG. PLATE 
PART NO. 
11700 
MTG. PLATE 
GASKET 
PART NO. 
330212 
 
**NOZZLE SIZE 
.70 X 45
° W 
NOZZLE 
PART NO. 
380702 
 
OIL PUMP 
PRESSURE 
130 LOW 
                          
                         170 HIGH 
BURNER 
G5D 
BURNER  
PART NO. 
380529 
 
Table 8:  Riello burner application
 
 
THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOLLOWED BY THE SPRAY 
ANGLE, IN DEGREE’S, AND THE SPRAY PATTERN, EITHER “H” FOR HOLLOW CONE OR “S” 
FOR SOLID CONE. FOR EXAMPLE, A NOZZLE RATED AT 0.65 GPH @ 100 PSIG THAT PROVIDES 
AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE 
TABLE AS “0.65 X 80
°H”. 
 
** NOTE:  The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner 
nozzles is that pre-set pump pressures are higher, therefore achieving the same firing rate with a smaller 
nozzle. 
 
OIL NOZZLE CAPACITY CHART 
 
UNITS
 
NOZZLE SIZE  
(GPH)
 
EQUIVALENT HEAT 
INPUT RATE* 
(BTU/HR)
 
EFFECTIVE  HEATING 
CAPACITY** 
(BTU/HR)
 
Beckett 
Riello 
OH6FA060D*** 
.50 
.50 
70,000 
60,000 
OH6FA072D*** 
.60 
.60 
85,000 
73,000 
OH6FA090D*** 
.75 
.70 
106,250 
90,000 
OH8FA101D*** 
.85 
.75 
119,000 
101,000 
OH8FA119D*** 
1.00 
.85 
140,000 
119,000 
OH8FA132D*** 
1.10 
1.00 
156,250 
132,000