Bryant 367AAN Manual De Usuario

Descargar
Página de 4
 
—3—
 
SPECIFICATIONS
 
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
† Permissible voltage limits for proper furnace operation. 
‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse recommended.
*** Beckett AFG-F6 requires field supplied and replacement burner firing head.
††  For unit 036105
‡‡ For unit 060120
ICS—Isolated Combustion System 
PSC—Permanent Split Capacitor 
As Factory Shipped.
 
UNIT SIZE
036105
060120
 
SHIPPING WEIGHT (Lb)
235
260
 
RATINGS AND PERFORMANCE
 
Input Btuh
70,000
91,000
105,000
119,000
140,000
154,000
Output Capacity*
Nonweatherized ICS
57,000
74,000
85,000
98,000
115,000
125,000
Nozzle—100 psig Pump Pressure
0.50—70W
0.65—70W
0.75—70B
0.85—70B
1.00—70W
1.10—70W
Firing Rate (GPH)
0.50
0.65
0.75
0.85
1.00
1.10
AFUE%*
Nonweatherized ICS
81.4
81.4
81.4
80.6
80.6
80.6
Certified Temperature Rise Range 
 
°
 
F
55—85
55—85
55—85
55—85
55—85
55—85
Recommended Heating Blower Speed
Med-Low
Med-High
High
Med-Low
Med-High
High
Heating CFM @ 0.2-in. wc Static Pressure
840
1130
1425
1220
1555
1890
Cooling CFM @ 0.5-in. wc Static Pressure
1250
1250
1250
1865
1865
1865
 
ELECTRICAL
 
Unit Volts—Hertz—Phase
115—60—1
Operating Voltage Range Min—Max†
104—132
Maximum Unit Amps
12.2
15.7
Minimum Wire Size (AWG)
14
Maximum Wire Length (Ft)‡
26
Maximum Fuse or Ckt Bkr Amps**
15
20
Transformer (24v)
40va
External Control
Heating
40va
Power Available
Cooling
30va
Air Conditioning Blower Relay
Standard
 
BURNER AND CONTROLS
 
Burner Model (3450 RPM)***
Beckett AFG-F3
Beckett AFG-F3
Beckett 
AFG-F6
Oil Pump Stages
1
Ignition Control
Continuous
Heating Blower Control (Off Delay)
Selectable 60, 90, 120, or 150 Sec
 
BLOWER DATA
 
Direct-Drive Motor HP (PSC)
1/3
3/4
Motor Full Load Amps
6.2
9.5
RPM (Nominal)—Speeds
1075—4
Blower Wheel Diameter X Width (In.)
10 X 8
12 X 10
Filter Size (In.)—Disposable
(2) 12 X 20 X 1
  (2) 16 X 20 X 1
 
FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS 
 
Electronic Air Cleaner
AIRA
Mechanical Air Cleaner
902B
Air Cleaner Cabinet
KEACA
Humidifier
Model 912D, 912E, 913B, 913C, or 914A
Heat Recovery Ventilator
Model VA3B, VB5B, or VC5B
Energy Recovery Ventilator
Model VL3A
Thermostat—Non-Programmable
For Use with 1-Speed Air Conditioner—TSTATBBNAC01-A
For Use with 2-Speed Air Conditioner—TSTATBBN2S01-A
For Use with 2-Speed Heat Pump—TSTATBBN2S01-A
Thermostat—Programmable
For Use with 1-Speed Air Conditioner—TSTATBBPAC01-A
For Use with 2-Speed Air Conditioner—TSTATBBP2S01-A
For Use with 1-Speed Heat Pump—TSTATBBPDF01-A
For Use with 2-Speed Heat Pump—TSTATBBP2S01-A or TSTATBBPDF01-A
Zoning—2-Zone
ZONEKIT2ZBDP, ZONEBB2KIT01
Zoning—4-Zone
ZONEBB4KIT01
Zoning—8-Zone
ZONEBB8KIT01
OIL NOZZLE KIT†† (QTY-50)
0.50 GPH    For 70,000 Btuh — KLANZ0150050
OIL NOZZLE KIT†† (QTY-50)
0.65 GPH    For 91,000 Btuh — KLANZ0250065
OIL NOZZLE KIT†† (QTY-50)
0.75 GPH    For 105,000 Btuh — KLANZ0350075
OIL NOZZLE KIT‡‡ (QTY-50)
0.85 GPH    For 120,000 Btuh — KLANZ0450085
OIL NOZZLE KIT‡‡ (QTY-50)
1.00 GPH    For 140,000 Btuh — KLANZ0550100
OIL NOZZLE KIT‡‡(QTY-50)
1.10 GPH    For 154,000 Btuh — KLANZ0650110