Amana S)8 Manual De Usuario

Descargar
Página de 48
19
G
AS
 S
UPPLY
 
AND
 P
IPING
24 V
AC
 H
UMIDIFIER
The yellow wire connected to the I.D. Blower pressure switch
is powered anytime the pressure switch is closed and
provides 24 VAC humidifier control. Remove the yellow wire
and connect the supplied brown jumper wire to the pressure
switch terminal. Reconnect the yellow wire to the “piggyback”
terminal on the brown jumper and then connect the 24 VAC
line of the humidifier to the stripped end of the brown wire.
Using a wire nut or a field-supplied quick connect terminal
can make this connection. The wiring must conform to all
local and national codes. Connect the COM side of the
humidifier to the B/C terminal on the furnace control board
(or to the COM side of the 24 VAC transformer). DO NOT
CONNECT 115V HUMIDIFIER TO THESE TERMINALS.
G
AS
 S
UPPLY
 
AND
 P
IPING
The furnace rating plate includes the approved furnace gas in-
put rating and gas types.  The furnace must be equipped to
operate on the type of gas applied.  This includes any conver-
sion kits required for alternate fuels and/or high altitude.
CAUTION
T
O
 
PREVENT
 
UNRELIABLE
 
OPERATION
 
OR
 
EQUIPMENT
 
DAMAGE
THE
 
INLET
 
GAS
 
SUPPLY
 
PRESSURE
 
MUST
 
BE
 
AS
 
SPECIFIED
 
ON
 
THE
 
UNIT
 
RATING
 
PLATE
 
WITH
 
ALL
 
OTHER
 
HOUSEHOLD
 
GAS
 
FIRED
 
APPLIANCES
 
OPERATING
.
Inlet gas supply pressures must be maintained within the ranges
specified in the following table.  The supply pressure must be
constant and available with all other household gas fired appli-
ances operating.  The minimum gas supply pressure must be
maintained to prevent unreliable ignition.  The maximum must
not be exceeded to prevent unit overfiring.
Natural Gas
Minimum: 5.0" w.c.
Maximum:10.0" w.c.
Propane Gas Minimum: 11.0" w.c.
Maximum:13.0" w.c.
Inlet Gas Supply Pressure
NOTE:  Adjusting the minimum supply pressure below the limits
in the above table could lead to unreliable ignition.  Gas input to
the burners must not exceed the rated input shown on the
rating plate. Overfiring of the furnace can result in premature
heat exchanger failure. Gas pressures in excess of 13 inches
water column can also cause permanent damage to the gas
valve.
At all altitudes, the manifold pressure must be within 0.3 inches
w.c. of that listed in the Specification Sheet applicable to your
model for the fuel used. At all altitudes and with either fuel, the
air temperature rise must be within the range listed on the fur-
nace nameplate.  Should this appliance be converted to LP,
refer to the instructions included in the factory authorized LP
conversion kit.
H
IGH
 A
LTITUDE
 D
ERATE
IMPORTANT NOTE: The furnace will naturally derate itself with
altitude. Do not attempt to increase the firing rate by changing
orifices or increasing the manifold pressure. This can cause
poor combustion and equipment failure.
High altitude installations may require both a pressure switch
and an orifice change.  These changes are necessary to com-
pensate for the natural reduction in the density of both the gas
fuel and the combustion air at higher altitude.
For installations above 7000 feet, please refer to your  distribu-
tor for required kit(s).
Contact the distributor for a tabular listing of appropriate
manufacturer’s kits for propane gas and/or high altitude instal-
lations.  The indicated kits must be used to insure safe and
proper furnace operation.  All conversions must be performed
by a qualified installer, or service agency.
P
ROPANE
 G
AS
 C
ONVERSION
WARNING
P
OSSIBLE
 
PROPERTY
 
DAMAGE
PERSONAL
 
INJURY
 
OR
 
DEATH
 
MAY
 
OCCUR
 
IF
 
THE
 
CORRECT
 
CONVERSION
 
KITS
 
ARE
 
NOT
 
INSTALLED
. T
HE
 
APPROPRIATE
 
KITS
 
MUST
 
BE
 
APPLIED
 
TO
 
ENSURE
 
SAFE
 
AND
 
PROPER
 
FURNACE
 
OPERATION
. A
LL
 
CONVERSIONS
 
MUST
 
BE
 
PERFORMED
 
BY
 
A
 
QUALIFIED
 
INSTALLER
 
OR
 
SERVICE
 
AGENCY
.
This unit is configured for natural gas.  The appropriate
manufacturer’s propane gas conversion kit, must be applied for
propane gas installations.  Refer to the “Propane Gas and/or
High Altitude Installations” section for details.
Models using Single Stage Gas Valves
Altitude
Gas
Kit
Orifice
Manifold
Pressure
Pressure
Switch 
#55
10.0" w.c.
NOTE:  In Canada, gas furnaces are certified to 4500 feet.
NOTE:  GMS81405DN** models utilize #43 orifices in Natural gas 
applications.
0-7000
Natural
None
#45
3.5" w.c.
None
Propane
LPT-03
Models using 2-Stage Gas Valves
High 
Stage
Low 
Stage
Natural
None
#45
3.5" w.c. 1.9" w.c.
None
Propane
LPM-06
#55
10.0" w.c. 6.0" w.c.
None
0-7000
NOTE:  In Canada, gas furnaces are only certified to 4500 feet.
NOTE:  GMH81405DN** models utilize #43 orifices in Natural gas 
applications.
Gas
Altitude
Kit
Orifice
Manifold Pressure Pressure
Switch 
Change