GME8
B
LOWER
 P
ERFORMANCE
 D
ATA
Tons AC
at 0.5"
0.6
0.7
0.8
ESP
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM
T1 - YELLOW
1.5
875
----
793
----
736
----
674
----
592
----
556
509
460
T2 - RED
2.0
1032
43
965
46
914
49
861
----
810
----
756
712
659
T3  -  ORANGE
2.5
1217
37
1153
39
1098
40
1051
42
1009
44
964
918
877
T4  -  BLUE
3.0
1365
33
1313
34
1268
35
1221
36
1172
38
1129 1086 1054
T5  -  BLACK
3.5
1549
29
1505
30
1460
30
1420
31
1378
32
1350 1305 1268
T1  -  YELLOW
2.5
1268
47
1198
49
1151
51
1092
54
1041
57
988
932
883
T2  -  RED
3.0
1362
44
1305
45
1261
47
1212
49
1170
51
1121 1074 1021
T3  -  ORANGE
3.5
1576
38
1519
39
1473
40
1426
42
1398
42
1341 1290 1252
T4  -  BLUE
4.0
1755
----
1711
35
1657
36
1627
36
1579
38
1548 1502 1463
T5 - BLACK
5.0
2183
----
2128
----
2094
----
2060
----
2014
----
1992 1944 1847
T1  -  YELLOW
3.0
1466
51
1415
52
1357
55
1306
57
1248
59
1202 1144 1088
T2  -  RED
3.5
1642
45
1596
46
1552
48
1499
49
1449
51
1388 1352 1306
T3  -  ORANGE
4.0
1750
42
1750
42
1707
43
1667
44
1610
46
1574 1531 1486
T4  -  BLUE
4.0
1870
40
1805
41
1782
42
1737
43
1701
44
1656 1606 1571
T5 - BLACK
5.0
2297
----
2297
----
2224
----
2106
35
2014
37
1896 1813 1669
Notes:
(CFM & Temperature Rise vs. External Static Pressure)
0.1
0.2
0.3
0.4
0.5
Model
Heating Speed
As Shipped
Motor Speed
EXTERNAL STATIC PRESSURE (Inches Water Column)
GME81005C***
•  CFM in chart is without filter(s).  Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two
    return filters, this chart assumes both filters are installed.
•  All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed.
GME80603B***
GME80805C***
•  For most jobs, about 375 - 400 CFM per ton when cooling is desirable.
•  Temperature rise data is based on 2nd-stage heat.  First-stage heat is 75% of rise indicated above.
•  INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
•  This chart is for information only.  For satisfactory operation, external static pressure should not exceed value shown on the rating plate.
•  The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same
    temperature rise at a particular CFM, while ESP at the CFM will be lower.
•  Factory Motor Speed Setting: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling.