Goodman Mfg MVC95 Manual De Usuario

Descargar
Página de 60
W
IRING
 D
IAGRAM
59
NO
FUSE 3 A
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
YL
MANUAL RESET
AUXILIARY
LIMIT CONTROL
PK
WARNING:DISCONNECT
TO  
MICR O
ID
40 VA
TRANSFORMER
PU
GY
N
NEUTRAL
BL
WIRING TO UNIT
10
DE
H
U
M
3
O
NO
PK
DIAG NO STIC 
LED 'S
BR
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO
    N.E.C. AND LOCAL CODES.
L
COLOR CODES:
IN
T
E
G
R
AT
E
D
 C
O
N
T
R
O
L M
O
DU
LE
1
LOW FIRE 
PRESSURE 
SWITCH
PS2 (12)
FLAME
SENSOR
HOT SURFACE
GN GREEN
OR
TR (11)
FRONT COVER 
PRESSURE SWITCH
YL
G
VAC
TO UNIT MUST BE
24
V
 H
U
M
.
HI
C
TH (4)
INDUCTOR COIL
24
V T
H
ER
M
O
S
T
AT
 C
O
N
N
EC
T
IO
N
S
GAS 
VALVE
RD
4
AND GROUNDED.
1
FS
GND
3
JU
C
T
IO
N
 B
O
X
BLWR
NEUTRAL
115
WH
W2
C
1
SWITCH (PRESS.)
FIELD SPLICE
FIELD GND
7
WARNING:
W2
LOW VOLTAGE FIELD
GROUNDED.
3
GN
BK
GY
5
OVERCURRENT PROTECTION DEVICE
3
BL
BR
1
13
MUST BE PROPERLY
TRANSFORMER
WH
NO
AUTO RESET PRIMARY 
LIMIT CONTROL
SWITCH
HLI (1)
1
NEUTRAL
OR
Y2
RD RED
ELECTRONIC
GY GRAY
Y1
WH
Y1
AIR
L
PU
NOTES:
70kBTU,90kBTU,
HLO (10)
GY
IGN
IND HI
BK
GND (5)
5
2
GY
R
ID BLOWER TWO-STAGE PRESSURE 
SWITCH ASSEMBLY
OR
OR
WH
SERVICING. WIRING
O
MVL (13)
EQUIPMENT GND
NO
       INTERNAL TO
W1
W1
24 V THERMOSTAT CONNECTIONS
PU
HIGH FIRE 
PRESSURE 
SWITCH
8
PROT. DEVICE
INTEGRATED CONTROL
PK
3. IF ANY OF THE ORIGINAL  WIRE AS SUPPLIED WITH THE 
    FURNACE MUST BE REPLACED, IT MUST BE REPLACED 
    WIRING MATERIAL HAVING A TEMPERATURE RATING OF  
    AT WITH LEAST 105°C. USE COPPER CONDUCTORS. 
PU
DISCONNECT
EAC
PLUG CONNECTION
2
FS
C
11
FRONT COVER 
PRESS. SW IT CH
POLARIZED AND
NEUTRAL
4
NEUTRAL
BR
BK
LINE
C
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
 DOOR OPEN)
NEUTRAL
SWITCH (TEMP.)
JUNCTION BOX
GND
1
R
CIRCULATOR 
BLOWER
1
PU  PURPLE
BLWR
JUNCTION
OR
HU
M
3
MANU AL RESET AU XILIARY LIMIT 
CONTR OLS
40 VA
Y2
14
IND LO
MANU AL RESET RO LLOUT 
LIM IT CO N TROLS
9
WH
N
PK PINK
HUMIDIFIER
INDOOR
HIGH FIRE 
PRESS. SW TICH
DISCONNECT
TWO STAGE
GAS VALVE
AIR CLEANER
C
ONLY
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE 
 
   
    USED WHEN SERVICING.
WH
PSO (7)
OVERCURRENT
HI VOLTAGE (115V)
2
HUM
2 CIRCUIT
CONNECTOR
LOW VOLTAGE (24V)
YL
GND
VAC
WH
C
H
ASSI
S GR
O
U
N
D
2
3
LOW FIRE 
PRESS. SWITCH
DOOR
WH
OR
NEUTRAL
2
MVC (8)
HOT
SURFACE
IGNITER
RD
WH
2
24V HUM.
IN
T
E
G
R
A
TE
D
 C
O
N
T
R
O
M
O
D
U
LE
LINE
5
DEHUM
BK BLACK
TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH
5. TO RECALL THE LAST  6 FAULTS, MOST RECENT TO LEAST
 
     RECENT,  DEPRESS SWITCH FOR MORE THAN 2 SECONDS
    IN STANDBY (NO THERMOSTAT INPUTS). 
G ND
YL
PU
C
115 VAC
6
BL BLUE
2
C
EAC
INDUCED
DRAFT 
BLOWER
15
FUSE
BK
WH WHITE
1
PM
BK
24
BLOWER COMPARTMENT
115 VAC/ 1Ø /60 HZ
IGNITER
0140F00530 REV. B
24V HUM.
 OVERCURRENT
BK
4
BR BROWN
BK
CIRCULATOR
C
YL YELLOW
PS1 (2)
OR
DI
P
 S
W
IT
C
H
E
S
BEFORE SERVICING.
AUTO R ESET PRIM ARY 
LIM IT CON TRO L
115kBTU MODELS
HI VOLTAGE FIELD
24 VAC
NO
ECM MTR 
HARNESS
PM
MVH (14)
OR ORANGE
BR
HI
TERMINAL
OR
GY
POWER BEFORE
INTEGRATED CO NTROL MODU LE
FLAME SENSOR
IGNITER
4
DISCONNECT POWER
RD
BK
2
C
TO
12
RD
LINE
POWER SUPPLY WITH
G
BR
24 V 
3 A
BURNER COMPARTMENT
PROTECTION DEVICE
GND
HUMIDIFIER
PROPERLY POLARIZED
BK
BL
GY
RD
BLWR
AIR
INDOOR
CIRCULATOR
TX (3)
RX (2)
+ VDC (1)
GND (4)
TO
R
TO
MICRO
TO +VDC
2
COOL
SEE 
NOTE 5
1
DELAY
T-STAT
2ND STG DLY
DEHUM
4
HEAT
ADJUST
3
UNU SED
HEAT OF F 
DELAY
NO
GR
C
BL
WH
MANUAL RESET ROLLOUT LIMIT 
CONTROLS (SINGLE CONTROL ON 
45 kBTU)
PK
70kBTU,90kBTU,
ONLY
115kBTU MODELS
GND
INDUCTOR COIL
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple
power sources may be present. Failure to do so may cause property
damage, personal injury or death.
*CVC9_AA, *MVC95_AA
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.