Goodman Mfg GKS9 Manual De Usuario

Descargar
Página de 14
14
WIRING DIAGRAMS
HIGH VOL
T
A
G
E
!
DIS
C
ONNECT
 AL
L
 POW
E
R BEF
O
RE
 SERVICI
NG OR IN
S
T
A
L
L
IN
G
 T
H
IS
UNIT
 M
U
L
T
IPL
E
 PO
W
E
R SO
UR
CES M
A
Y BE P
R
ESEN
T
 F
A
IL
URE 
T
O
DO SO 
M
A
Y CAUS
E PROP
ERT
Y
 DAM
AG
E, 
PERSONAL
 I
N
J
U
R
Y
 OR DE
A
T
H
.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GKS9*****X**
R
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
COLOR CODES:
LOW
 
VOLTAGE
 
(24V)
LOW
 
VOLTAGE
 
FIELD
HI
 
VOLTAGE
 
(115V)
HI
 
VOLTAGE
 
FIELD
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
0140F00236 REV. D
 
OR
 
(MED
 
LOW)
 
BL
 
(MED)
 
RD
 
(LOW)
GAS
 
VALVE
C2
C
G
W
       
INTERNAL
 
TO
INTEGRATED
 
CONTROL
JUNCTION
EQUIPMENT
 
GND
FIELD
 
GND
DIAGNOSTIC
LED
2
 
CIRCUIT
CONNECTOR
HOT
SURFACE
IGNITER
 
OVERCURRENT
PROT.
 
DEVICE
IGNITER
TH
 
(3)
INTEGRATED
CONTROL MODULE
JUNCTION
 
BOX
LINE-H
XFMR-H
IN
T
E
G
R
A
T
E
D
 C
O
N
T
R
O
M
O
D
U
L
E
IN
T
E
GR
A
T
E
D
 CO
NT
R
O
M
O
D
U
L
E
GND
DISCONNECT
L
N
OVERCURRENT
 
PROTECTION
 
DEVICE
RD
BL
BK
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED
BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105
TERMINAL
SWITCH
 
(PRESS.)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
PK
 
PINK
115
 
VAC
 
HOT
 
AND
 
PARK
 
TERMINALS
LINE-H
FLAME
SENSOR
BK
PLUG
 
CONNECTION
FIELD
 
SPLICE
SWITCH
 
(TEMP.)
OR
24V THERMOSTAT
CONNECTIONS
GR
GND
115 VAC
24 VAC
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
DOOR
SWITCH
BK
GND
L
N
WH
JUNCTION
 
BOX
1
OR
ID
 
BLOWER
PRESSURE
SWITCH
HEAT-H
GND
WH
RD
WH
GND
BURNER
 
COMPARTMENT
BLOWER
 
COMPARTMENT
NOTE
 
4
SEE
N
O
COOL-H
 
BK
 
(HI)
BR
BR
CAPACITOR
YL
WH
BL
PU
 
RD
OR
PK
BK
WH
WH
BLOWER
INDUCED
 
DRAFT
MANUAL
 
RESET
AUXILIARY
 
LIMIT
IN
 
UPFLOW
BLOWER
 
DECK
C
FS
HE
AT
-H
CO
OL
IGNITER
HOT
 
SURFACE
IND
IGN
BLWR
CIRCULATOR
BLWR
ID
FLAME
 
SENSOR
115
 
VAC
TRANSFORMER
40
 
VA
24
 
VAC
GND
RO1
 
(5)
RO2
 
(11)
HLO
 
(1)
HLI
 
(7)
MVC (9)
GND (8)
TR (6)
OR
WH
WH
BL
YL
OR
RD
GR
BR
 
PK
PK
WH
11
5
 V
A
C N
E
UTRA
L
BK
BK
BK
GY
2
4
V
 T
H
ER
MO
ST
A
T
 CO
NN
E
C
TI
O
N
S
MICRO
TO
C
G
Y
W
R
2
WH
OR
BL
YL
OR
PK
RD
OR
WH
XF
M
R
-H
TE
R
M
IN
A
L
S
BL
GY
GR
1
2
3
12
11
10
9
8
7
6
5
4
°C. USE COPPER CONDUCTORS ONLY.
24 VAC
HUMIDIFIER
24
 
VAC
HUMIDIFIER
HUMIDIFIER
PSO
 
(4)
MV(12)
PS
 
(10)
C
NO
ID BLOWER
PRESSURE
SWITCH
0
C
6
5
4
3
2
1
OFF
               
=
 
CONTROL
 
FAILURE
STEADY
 
ON
 
=
 
NORMAL
 
OPERATION
1 FLASH
 
      
=
2 FLASHES
  
=
 
PRESSURE
 
SWITCH
 
STUCK
 
CLOSED
3 FLASHES
  
=
 
PRESSURE
 
SWITCH
 
STUCK
 
OPEN
4 FLASHES
 
 
=
 
OPEN
 
HIGH
 
LIMIT
5 FLASHES
  
=
 
FLAME
 
SENSE
 
WITHOUT
 
GAS
 
VALVE
6 FLASHES
  
=
CONTINUOUS/RAPID
 
FLASHES
 
=
 
REVERSED
 
115
 
VAC
 
POLARITY
CONTROL
MODULE
INTEGRATED
FUSE
MI
GY
GY
M1
GAS
VALVE
C2
TO
 
115VAC/
 
1 Ø
 
/60
 
HZ
 
POWER
 
SUPPLY WITH
PU
Y
BR
GY
BR
LI
N
E
 NE
UT
R
A
L
S
NO
C
OPTIONAL
 
FRONT
 
COVER
PRESSURE
 
SWITCH
C
N
O
OPTIONAL
 
FRONT
 
COVER
PRESSURE
 