Entering Operating Parameters to Select Modes
To enter the display:
1. Press both the Up
and Down
keys for three seconds from the home page.
The word SEE will appear in the upper display and PAGE will appear in the lower
display.
display.
2. Press the Advance Key
to move through the parameter prompts.
3. Press the Up
or Down
keys to change the parameter value.
4. Press the RESET Key at any time to return to the Home Page display.
Figure 15: Setting List for Redundant Safety Controller (WATLOW), Part No. A0555757
Mode
Parameter Setting
range
Default
Manf. setting
SEn Sensor
Type
0-3
0
-
Lin
Thermocouple Linearization 0-10
0
H (1)
C-F
Temperature Units
Fahrenheit / Celsius
F
-
S.dEC
Temp. Decimal Places
0 – 0.0
0
-
IS.En
INFOSENSE™
Yes / No
No
-
Sc.Lo
Process Scale Low
4.00 to 20.00 mA
1.00 to 10.00V
1.00 to 10.00V
4.00 mA
1.00V
0
Sc.hi
Process Scale High
4.00 to 20.00 mA
1.00 to 10.00V
1.00 to 10.00V
20.00 mA
5.00 V
400
CAL Calibration
Offset
-999 to 999
0
-
Ftr.E Input
Filter
Off,
DiSP, Cont, both
OFF
-
Ot 1
Output 1 Function
Limit (2)
(2)
-
LSd1
Output 1 Limit Sides
Both, High, Low
Both
High
hyS1
Limit 1 Hysteresis
0.0 to 999.0
1.0
-
Ot2
Output 2 Function
Off / Process Alarm / Limit (2)
OFF
-
LSd2
Output 2 Sides
Both / high / low
Both
-
UdSP Upper
Display
Look
None, Process Value, Limit 1 Low Set,
Limit 1 High Set, Limit 2 Low Set, Limit
2 High Set, Alarm 2 Low Set, Alarm 2
High Set, Limit 3 Low Set, Limit 3 High
Set, Alarm 3 Low Set, Alarm 3 High Set
Limit 1 High Set, Limit 2 Low Set, Limit
2 High Set, Alarm 2 Low Set, Alarm 2
High Set, Limit 3 Low Set, Limit 3 High
Set, Alarm 3 Low Set, Alarm 3 High Set
Process -
LdSP Lower
Display
Look
None, Process Value, Limit 1 Low Set,
Limit 1 High Set, Limit 2 Low Set, Limit
2 High Set, Alarm 2 Low Set, Alarm 2
High Set, Limit 3 Low Set, Limit 3 High
Set, Alarm 3 Low Set, Alarm 3 High Set
Limit 1 High Set, Limit 2 Low Set, Limit
2 High Set, Alarm 2 Low Set, Alarm 2
High Set, Limit 3 Low Set, Limit 3 High
Set, Alarm 3 Low Set, Alarm 3 High Set
Limit 1
High Set
-
LOC Lockout
(0) no lockout, (1) Programming and
Setup Page Locked, (2) Limit Set
Points are the only Operation Page
parameters accessible, (3) Full
Lockout.
Setup Page Locked, (2) Limit Set
Points are the only Operation Page
parameters accessible, (3) Full
Lockout.
0 2