IV. MAINTENANCE 
1.  Inspect and clean lamp at least every 6 months. 
2.  Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity. 
The lamp should operate continuously for maximum lamp life and light effectiveness. 
V. REPLACEMENT PROCEDURE 
VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and disconnect from power source. 
1.  Remove wire tie or locking mechanism from latch on unit. 
2.  Unplug ballast plug from end of lamp. 
3.  Remove the wing nut on securing bracket. Swing out securing bracket to clear lamp. 
4.  Slide lamp out carefully. 
NOTE: When replacing the lamp, always wipe off lamp before installing. 
5.  Replace lamp following the appropriate procedure based on bracket selection in the installation section. 
6.  UV lamps contain a small amount of mercury, like a typical fluorescent lamp.  Check with your local waste 
management authority for local disposal or recycling requirements.  According to the EPA’s Universal Waste 
Rule, these types of lamps may be disposed of into household waste 
7.  After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to 
the housing and dated with the date of installation. 
8.  Replace wire tie or locking mechanism to latch. 
VI. TROUBLESHOOTING 
GUIDE 
1.  If unit does not light up replace bulb. 
2.  If unit still does not light up after replacing bulb, replace ballast.  
VII. 
REPLACEMENT PARTS LIST 
Lamp Length 
LAMP 
(Field Controls Part Number) 
BALLAST 
(Field Controls Part Number) 
12” 46365401  46365506 
18” 46365402  46365506 
28” 46365403  46365506 
For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at: 
Phone: 252-522-3031 
Fax: 252-522-0214 
Email: sales@fieldcontrols.com 
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause
permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum.
Avoid touching the glass portion of the lamp with your hands.