RISK OF ENTRAPMENT THAT MAY  
RESULT IN SERIOUS PERSONAL INJURY OR 
DEATH.  DISCONNECT POWER TO THE 
OPENER BEFORE AND DURING  
INSTALLATION OF AN ACCESSORY  
REVERSING DOOR EDGE OR 
PHOTOELECTRIC DEVICE.   DO NOT 
RECONNECT POWER TO OPENER UNTIL 
INSTRUCTED TO DO SO.  ENSURE DOORWAY 
IS CLEAR BEFORE STARTING TESTING OF 
UNIT. 
 
WARNING
 
TO PREVENT THE RISK OF PERSONAL INJURY 
AND/OR DAMAGE TO DOOR OR PROPERTY, 
ONLY OPERATE DOOR CONTROL WHEN 
DOOR IS IN CLEAR VIEW.  IF CONTROL 
STATION CANNOT BE LOCATED WHERE THE 
DOOR IS VISIBLE OR IF ANY OTHER DEVICE IS 
USED TO CONTROL THE DOOR AN AUXILIARY 
ENTRAPMENT DEVICE (DOOR EDGE OR 
PHOTOELECTRIC) MUST BE CONNECTED
 
WARNING
 
TO  PREVENT  THE  RISK  OF  PERSONAL  INJURY 
OR DEATH : 
• DISCONNECT POWER AT THE FUSE BOX  
   BEFORE PROCEEDING. 
• ELECTRICAL CONNECTIONS MUST BE MADE 
     BY A QUALIFIED INDIVIDUAL. 
• OBSERVE LOCAL ELECTRICAL CODES WHEN 
     WIRING THE OPERATOR. 
 
WARNING
 
WARNING: The J-S and H-S Series operators have 
been designed and constructed for use with voltages 
from 115 Volts AC to 480 Volts AC, in single or three 
phase. Check the operator nameplate label on the 
control box cover for the proper voltage and phase. The 
application of an improper input voltage or phase will 
result in catastrophic failure to the internal electrical 
components.
 
 
Observe local electrical codes when wiring the operator. 
 
When hard wiring, observe state and local electrical codes. A 
wiring diagram is attached to the inside of the control box cover. 
Connect the appropriate voltage and phase power leads to the 
appropriate terminals as per the wiring diagram and connect a 
ground wire to the grounding screw.  On three phase units, 
incorrect phasing of the power supply will cause the motor to 
rotate in the wrong direction (open when CLOSE button is pushed 
and vice versa).  To correct this, interchange any two of the 
incoming three phase conductors. 
 
The wiring diagram attached inside the cover of the control box 
details all of the field wiring terminal connections for the operator.  
Always connect the wires to the push-button controls and auxiliary 
devices exactly as shown. 
 
Warning:  Control voltage of the opener is 5 volts DC, Class 2.  
Do not run the power leads and control circuit wiring in the same 
electrical conduit. 
Note:  J-S and H-S Series model operators are pre-wired for 
entrapment protection devices. To operate in Momentary 
Contact To Close mode and comply with the UL325 
Entrapment Protection  requirements effective Aug. 29, 2010, 
an approved external entrapment device as described on Page 3 
must be installed and connected to the operator. Refer to Figure 
9 and the manufacturer‟s instructions to install and connect one 
of the approved door edge devices.  One or more contact 
sensors shall be located at the bottom edge of a vertically 
moving door.  Refer to the instructions on Page 12 for the 
Linear photoelectric system installation and wiring. 
 
If the external entrapment protection device is connected, the 
selector switches are set properly (Page 16) and the device 
detects an obstruction or becomes inactive, an opening door 
continues to open and a closing door stops, pauses and starts 
open. While in this mode, if a problem is detected while the 
operator is stopped, a close will require constant activation of 
the control Close button.  If an entrapment protection device as 
described above is attached and is properly working for 1 
second, it will be auto detected and the monitored function will 
be turned on
. Once the monitoring function is active, it will 
remain active even if the power is removed and the entrapment 
protection device is disconnected and power is restored. While 
in this mode, if a problem is detected while the operator is 
stopped, a close will require constant activation . 
 
Operators which have an operational entrapment protection 
device as described above may have one or more additional 
means of control which should be wired in accordance with the 
diagram supplied in the opener and also illustrated on Pages 20 
& 21.  To add a second three button station, refer to Figure 12. 
 
Number 22 gauge wire or heavier must be used for wiring 
the control stations and auxiliary control devices to the 
operator.  Smaller gauge wire will cause operational 
problems, especially when multiple push-button stations are 
used or during summer months.
 
INSTALLATION INSTRUCTIONS 